Semi-Hermetic Compressor Air-Cooled Condensing Unit(30HP-50HP)

Features of Before semi-hermetic compressor units Usability:

• The compressor unit can for use in many kinds of refrigerants such as R22, R134a, R404, R407C.

• The same serial compressor unit, is suitable for different applications.

Products Description

Message

Excellent functions:

• Equipped with oil separator, high and lower pressure controller, solenoid valve, filter drier, high and lower pressure gauge, big volume receiver and high efficient condensing units, it is good match unit.

Special design for the construction:

• Construction compact, equipped with protect cover,stability, service life long and good looking.

• Excellent design for the driving parts to rduced the vibration result.

• The reasonable suction device in order to compressor cylinder has completed cooling.

• According to different applications to equipment with high efficient Wpattern Rifle bored copper, it can be reduced overall dimension and add transfer-heating result.

• BFBV20 over 56H(Y) compressor unit adopted split wire motor, it can use small current to start running.

Reliability protectors:

• The motor uses electronic module protector or advanced heat protector to control the temperature.

• BFBV20 over 84.5H(Y)compress unit or adopted oil different pressure controller to ensure well lubrication system and equipped with auto-proctor of high pressure release valve.

• Crankcase heater fitted to prevent liquid migration.

 

UNIT MODEL INSTRUCTION

 

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R22  Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)   Power Consumption Pe(kw)
Evaporating temperature(℃)
10 7.5 5 0 -5 -10 -15 -20 -25

BFB-FJZ-

3HP

27

Qo

 

 

 

 

6880

5540

4450

4080

2680

Pe

 

 

 

 

2.98

2.66

2.37

1.95

1.58

32

Qo

 

 

 

 

6380

5073

4040

3070

2460

Pe

 

 

 

 

3.04

2.64

2.31

1.93

1.64

43

Qo

 

 

 

 

 

4600

3700

2740

2180

Pe

 

 

 

 

 

3.21

2.53

2.12

1.75

BFB-FJZ-

4HP

27

Qo

 

 

 

 

8280

6690

5420

4120

3220

Pe

 

 

 

 

3.49

2.90

2.62

2.05

1.63

32

Qo

 

 

 

 

8000

6400

5130

3910

3120

Pe

 

 

 

 

3.68

3.04

2.75

2.15

1.71

43

Qo

 

 

 

 

 

5540

4430

3260

2780

Pe

 

 

 

 

 

3.23

2.86

2.31

2.03

BFB-FJZ-

4HPH

27

Qo

13980

12910

11925

9950

8560

6830

5472

4165

3390

Pe

4.09

3.72

3.47

3.24

3.23

2.79

2.54

2.01

1.61

32

Qo

13350

12330

11395

95250

8188

6450

5187

3950

3190

Pe

4.24

3.85

3.62

3.40

3.26

2.93

2.64

2.03

1.63

43

Qo

 

 

12910

8900

7280

5790

4570

3360

2780

Pe

 

 

4.30

3.79

3.54

3.11

2.80

2.24

1.99

BFB-FJZ-

5HP

27

Qo

 

 

 

 

10580

8830

7240

6360

4540

Pe

 

 

 

 

4.46

3.84

3.49

2.88

2.25

32

Qo

 

 

 

 

10220

8450

6860

5570

4270

Pe

 

 

 

 

4.70

4.02

3.67

3.02

2.37

43

Qo

 

 

 

 

 

7530

6110

4780

3810

Pe

 

 

 

 

 

4.39

3.94

3.38

2.78

BFB-FJZ-

5HPH

27

Qo

18410

17010

15710

13600

11930

9020

7320

6430

4630

Pe

5.17

5.02

4.73

4.43

4.09

3.69

3.39

2.82

2.33

32

Qo

17570

16240

15010

13010

10460

8640

6930

5630

4360

Pe

5.35

5.19

4.95

4.64

4.33

3.87

3.53

2.85

2.25

43

Qo

 

 

14600

12350

9550

7870

6310

4930

3810

Pe

 

24930

5.67

5.19

4.65

4.22

3.86

3.28

2.72

BFB-FJZ-

8HPH

27

Qo

 

6.91

23020

19260

15780

12670

10080

8090

6350

Pe

 

 

6.63

5.80

5.30

5.00

4.67

3.84

3.59

32

Qo

 

 

22000

18420

15100

12130

8560

7670

5980

Pe

 

 

6.93

6.07

5.56

5.25

4.87

3.88

3.62

43

Qo

 

 

19670

16400

13480

11040

8710

6610

5220

Pe

 

 

7.38

6.84

6.39

5.93

5.33

4.66

4.02

BFB-FJZ-

10HP

27

Qo

 

 

 

 

21360

17870

14580

11740

9160

Pe

 

 

 

 

8.69

7.70

6.85

5.76

4.94

32

Qo

 

 

 

 

20650

17090

13820

11130

8610

Pe

 

 

 

 

9.16

8.07

7.19

6.05

5.19

43

Qo

 

 

 

 

 

15380

12550

10050

7680

Pe

 

 

 

 

 

8.72

7.87

7.02

5.60

BFB-FJZ-

10HPH

27

Qo

36020

33270

30730

26600

22070

18250

14740

11860

9340

Pe

9.92

9.33

9.02

8.54

8.06

7.40

6.64

5.64

4.89

32

Qo

34380

31770

29360

25440

21120

17480

13970

11250

8790

Pe

10.26

9.66

9.43

8.94

8.45

7.77

6.92

5.70

4.94

43

Qo

 

 

28260

23550

19360

16060

12950

10370

7680

Pe

 

 

10.67

9.86

9.21

8.38

7.72

6.81

4.49

BFB-FJZ-

15HP

27

Qo

 

 

 

 

31400

26000

21430

17350

13430

Pe

 

 

 

 

12.98

10.92

9.29

8.47

7.15

32

Qo

 

 

 

 

30350

24870

20300

16460

12620

Pe

 

 

 

 

13.69

11.45

9.75

8.89

7.52

43

Qo

 

 

 

 

 

22390

18370

14800

11260

Pe

 

 

 

 

 

13.03

11.24

9.50

8.20

BFB-FJZ-

15HPH

27

Qo

53090

49040

45290

39160

31800

25410

21660

17080

 

Pe

14.73

14.13

13.42

12.60

11.88

10.35

8.92

8.22

 

32

Qo

50680

46840

43080

37450

30430

24330

20530

16210

 

Pe

15.24

14.63

14.03

13.20

12.47

10.87

9.28

8.65

 

43

Qo

 

 

42530

35130

28460

22950

17620

14700

 

Pe

 

 

15.9

14.31

13.49

12.32

11.04

9.36

 

 

Note: The refrigerating effect is got on the basis of the degree of superheating of inlet air 25℃ and liquid with over-cold suction temperature of medium-high temperature compressor.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R22  Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw) Power Consumption Pe(kw)
Evaporating temperature(℃)
10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-FJZ-

V3HP

27

Qo

 

 

 

 

10460

8720

6840

5850

4750

3730

Pe

 

 

 

 

4.11

3.66

3.27

3.01

2.63

2.29

32

Qo

 

 

 

 

9790

8040

6350

5440

4350

3430

Pe

 

 

 

 

4.31

3.82

3.38

3.13

2.72

2.38

43

Qo

 

 

 

 

 

 

5420

4650

3570

2690

Pe

 

 

 

 

 

 

3.67

3.49

3.01

2.59

BFB-FJZ-

V5HPH

27

Qo

18610

17280

15960

13270

11020

9120

7190

6050

4810

5570

Pe

4.68

4.46

4.36

4.05

3.81

3.43

3.09

2.91

2.72

2.53

32

Qo

16640

15370

14100

11890

10330

8520

6680

5280

4520

3580

Pe

4.97

4.86

4.77

4.57

3.99

3.62

3.24

3.03

2.82

2.61

43

Qo

 

 

12560

10250

8790

7170

5610

4340

3070

 

Pe

 

 

5.41

4.96

4.46

3.94

3.53

3.32

3.11

 

BFB-FJZ-

V4HP

27

Qo

 

 

 

 

12150

10210

8160

7130

5760

4550

Pe

 

 

 

 

5.15

4.63

4.13

3.77

3.37

2.96

32

Qo

 

 

 

 

11450

9480

7540

6550

5270

4190

Pe

 

 

 

 

5.37

4.75

4.27

3.92

3.47

3.06

43

Qo

 

 

 

 

 

 

6410

5570

4290

3260

Pe

 

 

 

 

 

 

4.76

4.32

3.78

3.16

BFB-FJZ-

V6HPH

27

Qo

21640

20170

18710

15670

13110

10930

8680

7380

6080

4760

Pe

6.45

6.16

5.88

5.31

4.81

4.34

3.91

3.62

3.33

3.02

32

Qo

19310

17920

16490

14080

12250

9850

7870

6430

4980

3520

Pe

6.87

6.64

6.23

5.69

5.06

4.52

4.03

3.84

3.62

3.41

43

Qo

 

 

14570

11980

10350

8510

6610

5550

4490

 

Pe

 

 

7.04

6.29

5061

4.96

4.44

4.17

3.89

 

BFB-FJZ-

V5HP

27

Qo

 

 

 

 

15290

12790

10310

8610

7020

5540

Pe

 

 

 

 

6.06

5.45

4.82

4.38

3.92

3.48

32

Qo

 

 

 

 

14460

12060

9560

8010

6430

4940

Pe

 

 

 

 

6.36

5.65

5.06

4.57

4.06

3.57

43

Qo

 

 

 

 

 

 

8090

6750

5220

3960

Pe

 

 

 

 

 

 

5.38

4.87

4.38

3.91

BFB-FJZ-

V7HPH

27

Qo

26650

24840

23010

19240

16060

12940

10610

8910

6840

4760

Pe

7.25

6.98

6.71

6.17

5.72

5.16

4.67

4.23

3.76

3.27

32

Qo

23810

22740

21630

17870

15040

12210

9860

8130

6080

4130

Pe

7.81

7.47

7.18

6.65

6.01

5.44

4.91

4.41

3.92

3.51

43

Qo

 

 

18610

15320

12810

10290

8270

6780

5190

 

Pe

 

 

8.25

7.48

6.75

6.05

5.38

4.66

4.05

 

BFB-FJZ-

V6HP

27

Qo

 

 

 

 

17630

14840

12030

9780

7770

6010

Pe

 

 

 

 

7.52

6.71

6.01

5.37

4.74

4.14

32

Qo

 

 

 

 

16650

13820

11160

9010

7110

5410

Pe

 

 

 

 

7.95

7.05

6.27

5.55

4.89

4.21

43

Qo

 

 

 

 

 

 

9480

7290

5570

4330

Pe

 

 

 

 

 

 

6.74

6.08

5.28

4.38

BFB-FJZ-

V9HPH

27

Qo

31580

29460

27330

22910

19170

16010

12870

10400

7830

6310

Pe

9.31

8.87

8.42

7.67

7.01

6.36

5.76

5.19

4.63

4.05

32

Qo

29740

27710

25720

21310

17980

14950

11980

9420

7260

5350

Pe

10.04

9.54

9.03

8.15

7.41

6.71

6.08

5.38

4.68

4.05

43

Qo

 

 

 

 

15320

12620

9970

7840

5710

 

Pe

 

 

 

 

8.47

7.58

6.67

5.82

4.96

 

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R22 Watt(50Hz380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-FJZ-

V8HP

27

Qo

 

 

 

 

23570

19850

16280

13390

10610

8410

Pe

 

 

 

 

9.43

8.38

7.43

6.56

5.82

5.04

32

Qo

 

 

 

 

22090

18570

15210

12460

10060

7710

Pe

 

 

 

 

9.89

8.82

7.71

6.84

6.04

5.23

43

Qo

 

 

 

 

 

 

12930

10640

8210

6240

Pe

 

 

 

 

 

 

8.35

7.28

6.31

5.41

BFB-FJZ-

V12HPH

27

Qo

43610

38480

33350

28320

24260

20280

16510

13460

11410

8470

Pe

12.43

11.88

10.86

9.83

8.96

7.97

7.21

6.39

5.64

4.93

32

Qo

39860

35650

31340

27130

22730

18970

15420

12560

10620

7680

Pe

12.68

12.07

11.48

10.38

9.42

8.43

7.44

6.54

5.66

5.12

43

Qo

 

 

26640

23610

20070

16490

13310

10740

8610

 

Pe

 

 

13.06

11.64

10.46

9.25

8.11

7.09

6.59

 

BFB-FJZ-

V10HP

27

Qo

 

 

 

 

27330

22980

18830

15490

12630

9730

Pe

 

 

 

 

10.98

9.75

8.71

7.59

6.67

5.76

32

Qo

 

 

 

 

25670

21530

17590

14420

11650

8940

Pe

 

 

 

 

11.51

10.15

8.92

7.81

6.82

5.86

43

Qo

 

 

 

 

 

 

14950

12650

9530

7240

Pe

 

 

 

 

 

 

9.36

8.29

7.21

6.08

BFB-FJZ-

V15HPH

27

Qo

51650

48230

44610

36940

30860

25170

20210

16270

12950

10010

Pe

12.07

11.72

11.17

10.32

8.58

8.69

7.87

7.04

6.25

5.35

32

Qo

48680

45350

42010

33680

28720

23910

18950

15390

12060

9160

Pe

12.96

12.43

11.91

10.94

10.01

9.11

8.21

7.31

6.46

5.65

43

Qo

 

 

36520

31110

25620

20790

16940

13680

10480

 

Pe

 

 

13.46

12.28

11.15

10.13

8.95

7.96

6.89

 

BFB-FJZ-

V12HP

27

Qo

 

 

 

 

33340

27680

22860

18770

14640

11740

Pe

 

 

 

 

12.34

12.12

9.87

8.75

7.67

6.53

32

Qo

 

 

 

 

31370

26550

21670

17720

14140

10850

Pe

 

 

 

 

13.15

11.56

10.34

8.95

7.89

6.63

43

Qo

 

 

 

 

 

 

18820

15090

11640

8810

Pe

 

 

 

 

 

 

10.79

9.64

8.29

6.95

BFB-FJZ-

V20HPH

27

Qo

57660

53390

49910

41890

35540

29480

25060

19070

15050

11580

Pe

15.36

14.39

13.89

12.77

11.57

10.56

9.39

8.42

7.31

6.28

32

Qo

54600

50620

46790

39720

33740

27980

23810

18520

14630

11260

Pe

15.67

15.03

14.52

13.38

12.13

11.11

9.77

8.50

7.396.35

 

43

Qo

 

 

44110

36880

31060

25010

20630

16350

12700

 

Pe

 

 

15.05

14.47

13.01

12.13

10.38

8.94

6.35

 

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R22 Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-FJZ-

V15HP

27

Qo

 

 

 

 

42260

32940

29000

23330

18490

14360

Pe

 

 

 

 

16.44

14.40

12.76

11.22

9.54

8.53

32

Qo

 

 

 

 

40850

33510

26180

20270

17320

13280

Pe

 

 

 

 

17.33

14.93

13.17

11.51

10.14

8.6

43

Qo

 

 

 

 

 

30400

24960

19660

15330

11490

Pe

 

 

 

 

 

16.77

14.45

12.63

10.88

9.14

BFB-FJZ-

V25HPH

27

Qo

71850

67290

62150

52250

44370

36830

30480

24460

19380

15010

Pe

19.33

18.32

17.46

15.85

14.49

13.85

11.87

10.66

9.26

7.86

32

Qo

69440

64260

59250

50460

42890

35560

29390

23500

18500

 

Pe

19.60

18.80

18.14

16.61

15.28

13.83

12.27

10.54

8.91

 

43

Qo

 

 

56260

47091

39880

32930

27030

21490

16720

 

Pe

 

 

20.15

18.33

16.63

15.02

13.48

11.74

10.15

 

BFB-FJZ-

V20HP

27

Qo

 

 

 

 

48570

38460

33550

27010

21360

17100

Pe

 

 

 

 

19.14

16.74

14.75

13.1

11.66

10.09

32

Qo

 

 

 

 

47010

36840

31830

25600

20120

16300

Pe

 

 

 

 

20.18

17.55

15.48

13.76

12.26

10.40

43

Qo

 

 

 

 

 

33440

29040

22720

17780

13820

Pe

 

 

 

 

 

19.32

16.93

15.05

13.10

11.09

BFB-FJZ-

W25HP

27

Qo

 

 

 

 

61570

52120

43430

35530

28040

22190

Pe

 

 

 

 

26.71

23.43

20.32

17.36

14.76

12.84

32

Qo

 

 

 

 

56340

49260

40930

33360

26530

20440

Pe

 

 

 

 

27.17

24.61

21.43

18.25

15.57

13.17

43

Qo

 

 

 

 

 

45780

37460

29580

22470

16970

Pe

 

 

 

 

 

25.35

22.71

19.97

17.13

14.25

BFB-FJZ-

V30HPH

27

Qo

81830

76670

70900

59580

50660

40080

34910

28090

22450

17630

Pe

22.80

21.58

20.57

18.69

17.14

15.60

14.01

12.64

10.96

9.41

32

Qo

79100

73340

67850

57680

49100

38860

33890

27280

21820

17150

Pe

23.28

22.35

21.51

19.58

17.98

16.38

14.59

12.77

11.07

9.51

43

Qo

 

 

64170

53830

45640

35960

31160

24960

19660

 

Pe

 

 

23.87

21.62

19.57

17.78

16.03

14.21

12.64

 

BFB-FJZ-

W30HP

27

Qo

 

 

 

 

72860

60650

50330

40610

32140

24860

Pe

 

 

 

 

28.40

24.81

22.00

19.41

17.31

15.05

32

Qo

 

 

 

 

70310

57870

47490

38300

29950

23450

Pe

 

 

 

 

30.46

26.27

23.36

20.75

18.16

15.48

43

Qo

 

 

 

 

 

52770

43550

34170

26740

20130

Pe

 

 

 

 

 

28.58

25.14

22.30

19.46

16.48

BFB-FJZ-

W35HPH

27

Qo

103830

97250

89860

75570

64220

54310

45210

37120

29390

23590

Pe

29.39

28.15

26.84

25.03

22.31

21.88

19.18

16.73

13.91

11.89

32

Qo

94920

87820

81330

69220

58800

51970

43550

35410

28650

 

Pe

31.64

30.29

28.98

26.19

23.91

22.92

19.91

16.82

14.61

 

43

Qo

 

 

78420

62350

56110

49220

40190

32410

24870

 

Pe

 

 

31.54

28.76

26.14

23.33

21.46

18.81

16.52

 

BFB-FJZ-

W40HPH

27

Qo

122860

115080

106340

89420

75990

63200

52390

42430

33690

26430

Pe

33.52

32.10

30.60

28.54

25.44

23.17

20.77

18.71

16.30

13.94

32

Qo

118460

109660

101500

86390

73380

61050

50530

40650

32340

 

Pe

35.48

33.96

32.50

29.38

26.81

24.47

21.69

19.12

17.04

 

43

Qo

 

 

96380

80850

68490

56740

46720

37440

29600

 

Pe

 

 

35.40

32.11

29.07

26.30

23.76

21.00

18.77

 

BFB-FJZ-

W40HP

27

Qo

 

 

 

 

86160

71870

59840

48480

38460

29990

Pe

 

 

 

 

34.85

30.47

27.10

24.06

20.86

18.06

32

Qo

 

 

 

 

83380

68840

56790

46060

36220

28590

Pe

 

 

 

 

36.75

31.94

28.44

25.26

21.93

18.61

43

Qo

 

 

 

 

 

62770

52070

41070

32350

24520

Pe

 

 

 

 

 

34.73

30.60

27.10

23.46

19.80

BFB-FJZ-

W50HPH

27

Qo

144460

135400

125260

105490

89860

74890

62280

50420

40470

32020

Pe

42.26

40.39

38.34

34.72

31.71

28.91

25.90

23.38

20.55

17.67

32

Qo

139640

129510

119870

102120

87080

72620

60450

48960

39330

31160

Pe

43.17

41.82

40.08

36.38

33.27

30.36

26.96

23.62

20.77

17.86

43

Qo

 

 

113700

95580

81190

67490

55870

45060

35920

 

Pe

 

 

43.67

39.77

36.10

32.70

29.50

25.90

22.80

 

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold..

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R134a  Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-FJZ-

3HPY

27

Qo

8240

7406

6950

5980

5610

4580

3140

2130

1620

1090

Pe

2.22

2.12

2.01

1.92

1.68

1.54

1.38

1.09

0.88

0.66

32

Qo

7700

7160

6590

5730

4310

3540

2880

1910

1620

1100

Pe

259

2.52

2.42

2.26

1.96

1.79

1.52

1.16

1.07

0.81

43

Qo

7300

6360

5710

4820

3910

3120

2504

1590

 

 

Pe

2.76

2.66

2.46

2.31

1.99

1.81

1.54

1.18

 

 

BFB-FJZ-

4HPY

27

Qo

9880

9060

8380

7030

6130

4830

3840

2670

1960

1370

Pe

2.60

2.46

2.35

2.10

1.97

1.74

1.54

1.18

1.08

0.75

32

Qo

9330

8660

8040

6820

5550

4450

3520

2330

1890

1330

Pe

2.99

2.85

2.70

2.45

2.20

1.96

1.65

1.25

1.13

0.87

43

Qo

8040

7540

6980

5970

4870

3830

3030

1960

 

 

Pe

3.45

3.12

2.98

2.76

2.54

2.23

1.86

1.52

 

 

BFB-FJZ-

5HPY

27

Qo

13000

11900

11000

9600

7820

6440

5170

3800

3200

2310

Pe

3.12

2.96

2.82

2.68

2.45

2.25

2.00

1.65

1.35

1.01

32

Qo

11750

10840

9900

9100

7290

6050

4860

3700

2840

1900

Pe

3.89

3.77

3.70

3.43

2.96

2.69

2.30

2.14

2.12

1.84

43

Qo

11000

10300

9550

8280

6390

5200

4190

2860

 

 

Pe

4.39

4.21

4.04

3.78

3.21

2.89

2.64

1.94

 

 

BFB-FJZ-

8HPHY

27

Qo

19020

14730

13360

12610

11080

9050

7110

5190

3890

 

Pe

5.00

4.75

4.53

4.06

3.16

3.22

2.82

2.26

1.87

 

32

Qo

17190

13960

12790

11870

10290

8480

6710

4590

3364

 

Pe

5.25

5.10

5.00

4.56

4.19

3.77

3.21

2.44

2.10

 

43

Qo

14770

12980

11960

10990

9080

7400

5770

3860

 

 

Pe

6.17

6.00

5.88

5.40

4.92

4.43

3.77

2.87

 

 

BFB-FJZ-

10HPY

27

Qo

25460

23340

21610

18810

15800

13050

10420

7620

5740

 

Pe

6.70

6.34

6.05

5.61

5.06

4.38

4.09

3.32

2.76

 

32

Qo

24700

22300

21260

18050

14780

12350

9890

7200

5240

 

Pe

7.55

7.33

7.18

6.55

5.70

5.45

4.64

3.76

3.10

 

43

Qo

21260

19980

18460

15800

12970

10630

8610

6030

 

 

Pe

8.49

8.16

7.82

7.21

6.66

5.95

5.1

3.96

 

 

BFB-FJZ-

15HPY

27

Qo

36700

33660

31000

27120

22710

18630

15030

11000

8270

5940

Pe

9.88

9.36

8.92

8.26

7.42

6.77

5.05

4.89

4.05

3.27

32

Qo

35050

32460

30050

26150

21160

17270

14300

10440

7550

5450

Pe

11.36

11.02

10.82

9.77

8.86

7.75

6.91

5.70

4.53

3.62

43

Qo

31100

28870

26970

22880

18560

14590

12190

8660

 

 

Pe

12.68

12.14

11.65

10.64

9.41

8.24

7.43

5.78

 

 

 

Note: The refrigerating effect is got on the basis of the degree of superheating of inlet air 20℃and liquid with over-cold.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R134a  Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-FJZ-

V3HPY

27

Qo

12230

11280

10360

8460

6960

5620

4380

3410

2620

1890

Pe

2.83

2.74

2.61

2.39

2.21

1.97

1.75

1.54

1.31

1.07

32

Qo

11160

10320

9450

7970

6490

5250

4160

3210

2390

1780

Pe

2.99

2.88

2.76

2.54

2.32

2.09

1.86

1.61

1.35

1.08

43

Qo

9980

9210

8420

6880

5630

4480

3440

2610

1940

1330

Pe

3.31

3.18

3.03

2.79

2.53

2.26

1.98

1.69

1.39

1.11

BFB-FJZ-

V4HPY

27

Qo

14830

13740

12670

10680

8710

7050

5550

4470

3440

2580

Pe

4.09

3.94

3.78

3.47

3.17

2.87

2.57

2.28

1.97

1.68

32

Qo

13910

12870

11880

9810

8140

6570

5270

4130

3150

2330

Pe

4.29

4.13

3.99

3.66

3.32

2.98

2.65

2.31

1.98

1.71

43

Qo

11930

11010

10180

8380

6920

5550

4390

3380

2540

1830

Pe

4.81

4.62

4.44

4.01

3.56

3.17

2.76

2.37

1.95

1.54

BFB-FJZ-

V5HPY

27

Qo

18420

17060

15680

12920

10720

8670

6950

5450

4140

3050

Pe

4.67

4.48

4.32

3.94

3.57

3.21

2.86

2.48

2.14

1.75

32

Qo

17340

16030

14750

12130

10050

8100

6470

5040

3950

2770

Pe

4.95

4.76

4.58

4.13

3.74

3.35

2.97

2.57

2.21

1.81

43

Qo

15000

13860

12730

10340

8610

6890

5460

4200

3110

2190

Pe

5.51

5.32

5.09

4.64

4.18

3.68

3.24

2.74

2.29

1.79

BFB-FJZ-

V6HPY

27

Qo

21060

19580

18060

14980

12510

10160

8200

6480

5040

3750

Pe

5.94

5.67

5.42

4.88

4.31

3.85

3.37

2.89

2.46

2.03

32

Qo

19790

18380

16960

14050

11710

9050

7640

6010

4630

3410

Pe

6.26

5.94

5.66

5.09

4.54

4.03

3.49

2.99

2.53

2.05

43

Qo

17070

15850

14620

12080

10040

8100

6460

5050

3790

2710

Pe

6.92

6.61

6.31

5.61

5.04

4.42

3.77

3.21

2.61

2.06

BFB-FJZ-

V8HPY

27

Qo

27190

25260

23340

19360

16150

13120

10570

8320

6450

4770

Pe

7.74

7.38

7.03

6.32

5.61

5.04

4.46

3.89

3.38

2.89

32

Qo

25470

23680

21850

18110

15080

12220

9820

7680

5880

4280

Pe

8.13

7.74

7.37

6.61

5.82

5.21

4.51

3.94

3.36

2.83

43

Qo

21680

20130

18570

15350

12720

10230

8110

6240

4640

3220

Pe

8.81

8.38

7.97

7.08

6.25

5.44

4.64

3.95

3.26

2.63

BFB-FJZ-

V10HPY

27

Qo

31560

29360

27120

22480

18750

15220

12230

9610

7400

5420

Pe

9.01

8.63

8.21

7.41

6.64

5.91

5.19

4.51

3.83

3.21

32

Qo

29530

27460

25350

21010

17320

14160

11460

8840

6730

4840

Pe

9.43

9.02

8.59

7.69

6.87

6.07

5.29

4.54

3.82

3.16

43

Qo

25090

23280

21500

17760

14710

11830

9340

7150

5270

3580

Pe

10.26

9.74

9.25

8.21

7.23

6.29

5.38

4.54

3.72

2.94

BFB-FJZ-

V12HPY

27

Qo

38040

34670

32520

27440

22910

19190

14880

11330

8970

6630

Pe

10.31

9.53

9.21

8.45

7.45

6.85

5.84

5.11

4.63

3.87

32

Qo

35740

33430

30560

25760

21390

17380

13870

10750

8230

5940

Pe

10.88

10.26

9.78

8.74

7.87

6.89

6.04

5.70

4.52

3.72

43

Qo

30660

29740

26200

21890

18070

14730

11650

8930

6560

4530

Pe

11.82

11.23

10.53

9.43

8.25

7.38

6.31

5.26

4.35

3.54

BFB-FJZ-

V15HPY

27

Qo

49170

44980

41580

34810

29280

23780

18960

14750

11220

8040

Pe

11.61

12.37

11.62

10.30

9.07

8.07

7.18

6.18

5.30

4.36

32

Qo

46150

42640

39290

32690

25780

21410

16310

13350

9820

6870

Pe

14.12

13.43

12.42

11.13

9.94

8.81

7.61

6.46

5.56

4.52

43

Qo

43770

38330

34040

27500

23400

18850

14950

11080

 

 

Pe

15.07

14.20

12.87

11.35

10.09

8.89

7.72

6.63

 

 

BFB-FJZ-

V20HPY

27

Qo

60760

50700

46840

36900

33040

26850

21460

16720

12760

9200

Pe

15.65

14.69

13.88

12.36

11.00

9.80

8.61

7.52

6.27

5.19

32

Qo

51960

47990

44270

36900

30030

24500

19560

15220

11250

7940

Pe

16.53

15.60

15.22

13.23

11.81

10.40

9.00

7.62

6.99

5.30

43

Qo

49600

41200

38370

31060

26500

21400

17200

12260

 

 

Pe

17.64

16.48

15.25

13.50

12.00

10.50

9.13

7.82

 

 

BFB-FJZ-

W25HPY

27

Qo

71810

65880

60890

51560

42960

35170

28220

22110

16830

12330

Pe

20.99

19.66

18.58

16.32

14.12

12.43

10.78

9.34

7.98

6.68

32

Qo

66830

62350

57480

48620

40440

33020

26400

20600

15580

11310

Pe

21.39

20.41

19.23

16.75

14.62

12.73

11.09

9.61

8.11

6.67

43

Qo

56060

51980

50140

42320

35080

28490

22620

17460

 

 

Pe

23.67

21.98

20.46

17.72

15.39

13.35

11.52

9.82

 

 

BFB-FJZ-

W30HPY

27

Qo

82900

76050

70290

60310

49640

40320

32190

25010

19140

13790

Pe

23.30

21.82

20.62

18.41

16.27

14.47

12.84

11.17

9.40

7.68

32

Qo

77230

72050

66420

55310

45030

36750

29330

22240

16870

11900

Pe

24.61

23.47

22.12

19.59

17.50

15.47

13.33

11.27

9.64

7.80

43

Qo

68380

63400

61160

49460

40530

32410

25900

19920

 

 

Pe

26.74

24.83

23.11

20.49

18.02

15.73

13.54

11.32

 

 

BFB-FJZ-

W40HPY

27

Qo

97580

89470

82750

71080

58650

47770

38250

29900

23000

16730

Pe

27.36

25.66

24.24

21.61

19.14

17.05

15.12

13.15

11.07

9.10

32

Qo

91000

85000

78430

65500

53420

43880

35130

24470

20500

14660

Pe

29.34

27.90

26.81

23.09

20.59

18.16

15.63

13.20

11.09

9.21

43

Qo

81190

74980

68450

58650

48100

38780

31150

23980

 

 

Pe

32.01

29.67

27.50

24.16

21.19

18.48

15.89

13.27

 

 

 

Note: The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-FJZ-

3HPY

27

Qo

 

 

 

5990

4890

3800

3060

2300

1760

1260

Pe

 

 

 

3.22

2.95

2.34

1.84

1.51

1.31

1.08

32

Qo

 

 

 

5863

4670

3560

2900

2230

1690

1170

Pe

 

 

 

3.87

3.15

2.6

2.04

1.67

1.38

0.97

43

Qo

 

 

 

 

 

 

2640

1980

1450

1070

Pe

 

 

 

 

 

 

2.07

1.71

1.4

0.99

BFB-FJZ-

4HPY

27

Qo

 

 

 

7780

5950

4650

3830

2780

1900

1560

Pe

 

 

 

3.77

3.35

2.58

2.05

1.74

1.42

1.09

32

Qo

 

 

 

7440

5690

4460

3670

2560

1830

1500

Pe

 

 

 

3.98

3.50

2.71

2.15

1.81

1.46

1.12

43

Qo

 

 

 

 

 

 

3320

2390

1750

1200

Pe

 

 

 

 

 

 

2.37

1.94

1.60

1.17

BFB-FJZ-

4HPHY

27

Qo

12720

10700

9270

7960

6080

4750

3950

2870

2090

1630

Pe

4.34

4.06

3.86

3.50

3.22

2.51

2.01

1.71

1.41

1.09

32

Qo

12150

10230

8970

7700

5820

4510

3680

2670

1980

1460

Pe

4.49

4.24

4.05

3.67

3.38

2.61

2.05

1.74

1.44

1.10

43

Qo

 

 

 

 

 

 

3460

2440

1800

1230

Pe

 

 

 

 

 

 

2.32

1.92

1.48

1.06

BFB-FJZ-

5HPY

27

Qo

 

 

 

9660

7960

6620

5240

3900

3000

2160

Pe

 

 

 

4.98

4.46

3.64

2.86

1.96

1.59

1.23

32

Qo

 

 

 

9230

7610

6340

5030

3740

2880

2080

Pe

 

 

 

5.25

4.68

3.82

2.99

2.04

1.64

1.25

43

Qo

 

 

 

 

 

 

4550

3450

2540

1660

Pe

 

 

 

 

 

 

3.24

2.65

2.07

1.45

BFB-FJZ-

5HPHY

27

Qo

16760

14620

11850

9870

8130

6760

5400

4050

3140

2250

Pe

5.92

5.53

5.13

4.62

4.29

3.53

2.83

1.92

1.57

1.21

32

Qo

15990

13970

11460

9550

7790

6410

5030

3710

2800

2020

Pe

6.12

5.78

5.38

4.85

4.50

3.67

2.90

1.96

1.60

1.23

43

Qo

 

 

 

 

 

 

4740

3620

2540

1680

Pe

 

 

 

 

 

 

3.18

2.63

2.03

1.44

BFB-FJZ-

8HPHY

27

Qo

24560

20700

17110

13860

11200

9220

7410

5940

4590

3300

Pe

8.31

7.25

6.59

6.05

5.59

4.80

4.49

3.81

3.14

2.43

32

Qo

23440

19780

16540

13410

10730

8740

6900

5430

4100

2970

Pe

8.60

7.76

6.91

6.35

5.87

5.00

4.58

3.89

3.21

2.46

43

Qo

 

 

 

 

 

 

6490

4970

3480

2300

Pe

 

 

 

 

 

 

4.68

4.01

3.32

2.55

BFB-FJZ-

10HPY

27

Qo

 

 

 

19540

16030

13230

10580

8400

6450

4630

Pe

 

 

 

10.00

8.77

7.27

6.23

5.30

4.31

3.35

32

Qo

 

 

 

18670

15330

12680

10150

8070

6210

4470

Pe

 

 

 

10.54

9.19

7.63

6.54

5.51

4.44

3.42

43

Qo

 

 

 

 

 

 

9170

7300

5120

3360

Pe

 

 

 

 

 

 

6.83

5.60

4.55

3.61

BFB-FJZ-

10HPHY

27

Qo

32770

28590

23920

19970

16370

13420

10910

8640

6750

4850

Pe

11.37

10.67

10.02

9.27

8.43

7.06

6.11

5.19

4.18

3.32

32

Qo

31280

27320

23140

19320

15680

12720

10150

7900

6030

4360

Pe

11.76

11.16

10.49

9.37

8.85

7.34

6.23

5.30

4.36

3.35

43

Qo

 

 

 

 

 

 

9550

7590

5120

3390

Pe

 

 

 

 

 

 

6.40

5.57

4.42

3.65

BFB-FJZ-

15HPY

27

Qo

 

 

 

28420

23550

19480

15510

12370

9500

6850

Pe

 

 

 

14.18

11.90

10.70

9.03

7.68

5.95

4.80

32

Qo

 

 

 

27160

22530

18660

14880

11880

9150

6610

Pe

 

 

 

14.95

12.47

11.23

9.48

7.99

6.13

4.90

43

Qo

 

 

 

 

 

 

13440

9050

6660

4370

Pe

 

 

 

 

 

 

9.56

8.12

6.25

4.98

BFB-FJZ-

15HPHY

27

Qo

48300

42090

34470

28420

24060

19690

15840

12740

9840

7080

Pe

16.80

15.71

14.77

12.96

11.46

10.33

8.82

7.33

5.82

4.56

32

Qo

46110

40220

33330

26900

23040

18680

14740

11640

8790

6360

Pe

17.38

16.42

15.48

13.60

12.03

10.76

9.00

7.48

5.94

4.60

43

Qo

 

 

 

 

 

 

13870

9410

6590

4360

Pe

 

 

 

 

 

 

9.26

7.62

6.04

4.66

 

Note: The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)   Power Consumption Pe(kw)
Evaporating temperature(℃)
5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-FJZ-

V3HPY

27

Qo

 

 

10570

8970

7580

6370

4980

4020

3080

2320

Pe

   

4.78

4.27

3.86

3.43

3.07

2.68

2.26

1.92

32

Qo

   

9620

8240

6960

5770

4590

3650

2810

2080

Pe

 

 

4.95

4.44

3.97

3.52

3.13

2.71

2.29

1.89

43

Qo

 

 

 

 

 

 

3730

2920

2190

1580

Pe

 

 

 

 

 

 

3.21

2.73

2.28

1.83

BFB-FJZ-

V5HPHY

27

Qo

15830

13450

11420

9690

8110

6690

5420

4310

3320

2470

Pe

5.02

4.69

4.38

4.04

3.68

3.29

2.94

2.59

2.18

1.84

32

Qo

14590

12400

10630

8920

7540

6130

4950

3940

2980

2190

Pe

5.32

4.95

4.62

4.23

3.81

3.45

3.05

2.64

2.24

1.83

43

Qo

 

 

 

 

 

4920

3920

3050

2270

1610

Pe

 

 

 

 

 

3.63

3.15

2.69

2.22

1.75

BFB-FJZ-

V4HPY

27

Qo

 

 

12270

10510

8960

7510

6040

4950

3860

2910

Pe

 

 

5.86

5.28

4.73

4.21

3.68

3.18

2.71

2.24

32

Qo

 

 

11110

9610

8180

6850

5610

4480

3460

2560

Pe

 

 

6.08

5.47

4.87

4.31

3.75

3.22

2.71

2.21

43

Qo

 

 

 

 

 

 

4420

3480

2660

1875

Pe

 

 

 

 

 

 

3.86

3.26

2.66

2.11

BFB-FJZ-

V6HPHY

27

Qo

18680

16010

13830

11680

9840

8150

6630

5270

4100

3040

Pe

6.66

6.17

5.67

5.17

4.67

4.17

3.68

3.19

2.71

2.24

32

Qo

17160

14710

12570

10720

9020

7440

6030

4760

3680

2690

Pe

7.01

6.47

5.92

5.38

4.89

4.33

3.81

3.26

2.74

2.22

43

Qo

 

 

 

 

 

5940

4750

3680

2770

1930

Pe

 

 

 

 

 

4.49

3.87

3.25

2.67

2.09

BFB-FJZ-

V5HPY

27

Qo

 

 

15710

13380

11340

9460

7750

6210

4880

3660

Pe

 

 

6.89

6.28

5.67

5.06

4.45

3.85

3.27

2.69

32

Qo

 

 

14400

12260

10390

8650

7060

5620

4390

3240

Pe

 

 

7.21

6.53

5.92

5.25

4.59

3.94

3.31

2.67

43

Qo

 

 

 

 

 

 

5610

4420

3360

2370

Pe

 

 

 

 

 

 

4.74

4.11

3.31

2.61

BFB-FJZ-

V7HPHY

27

Qo

22680

19360

16680

14050

11780

9730

7870

6230

4820

3550

Pe

7.65

7.12

6.58

6.02

5.45

4.89

4.36

3.79

3.22

2.63

32

Qo

20860

17810

15180

12920

10810

8890

7240

5630

4320

3130

Pe

8.06

7.49

6.89

6.29

5.73

5.09

4.42

3.84

3.21

2.61

43

Qo

 

 

 

 

 

7110

5670

4370

3260

2250

Pe

 

 

 

 

 

5.33

4.59

3.85

3.15

2.43

BFB-FJZ-

V6HPY

27

Qo

 

 

17800

15260

13040

10960

9040

7310

5810

4410

Pe

 

 

8.68

7.83

7.01

6.22

5.44

4.71

3.98

3.29

32

Qo

 

 

16320

13990

11940

10020

8250

6640

5240

3940

Pe

 

 

9.08

8.18

7.36

6.49

5.59

4.79

4.05

3.31

43

Qo

 

 

 

 

 

 

6560

5210

4030

3360

Pe

 

 

 

 

 

 

5.94

4.99

4.12

3.24

BFB-FJZ-

V9HPHY

27

Qo

26830

23010

19920

16850

14220

11820

9660

7730

6090

4610

Pe

9.47

8.79

8.09

7.39

6.71

6.02

5.32

4.64

3.96

3.29

32

Qo

24730

21230

18190

15550

13110

10870

8860

7050

5520

4110

Pe

10.03

9.29

8.53

7.77

6.99

6.24

5.48

4.77

4.03

3.31

43

Qo

 

 

 

 

 

8810

7110

5560

4230

3020

Pe

 

 

 

 

 

6.82

5.89

4.99

4.06

3.25

 

Note: The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-FJZ-

V8HPY

27

Qo

 

 

 

19720

16580

14130

11610

9310

7330

5490

Pe  

 

 

9.69

8.57

7.53

6.57

5.64

4.76

3.91

32

Qo

 

 

 

18140

15390

12890

10550

8420

6560

4840

Pe

 

 

 

9.97

8.78

7.76

6.73

5.69

4.79

3.89

43

Qo

 

 

 

 

 

 

8320

6540

4980

3530

Pe

 

 

 

 

 

 

6.82

5.72

4.69

3.64

BFB-FJZ-

V12HPHY

27

Qo

31830

27630

24120

20520

17370

14430

11740

9320

7230

5310

Pe

12.43

11.32

10.25

9.21

8.22

7.27

6.36

5.46

4.59

3.75

32

Qo

29100

25320

22110

18810

15920

13190

10680

8440

6480

3670

Pe

12.97

11.73

10.59

9.58

8.44

7.42

6.51

5.57

4.65

3.76

43

Qo

 

 

 

 

 

10510

8430

6550

4890

3370

Pe

 

 

 

 

 

7.69

6.56

5.55

4.53

3.56

BFB-FJZ-

V10HPY

27

Qo

 

 

 

22930

19550

16380

13440

10760

8440

6280

Pe

 

 

 

11.24

9.92

8.69

7.53

6.45

5.44

4.47

32

Qo

 

 

 

21020

17910

14970

12230

9740

7570

5550

Pe

 

 

 

11.53

10.16

8.94

7.63

6.49

5.46

4.43

43

Qo

 

 

 

 

 

 

9690

7610

5770

4060

Pe

 

 

 

 

 

 

7.67

6.47

5.22

4.09

BFB-FJZ-

V15HPHY

27

Qo

44710

38020

32590

27290

22740

18620

14930

11640

8890

6340

Pe

13.21

12.11

11.07

10.09

9.11

8.16

7.19

6.22

5.25

4.31

32

Qo

41140

35020

29710

25120

20910

17110

13660

10610

8020

5670

Pe

13.89

12.64

11.51

10.42

9.37

8.34

7.38

6.34

5.31

4.29

43

Qo

 

 

 

 

 

13600

10730

8190

6030

4080

Pe

 

 

 

 

 

8.59

7.42

6.26

5.17

4.02

BFB-FJZ-

V12HPY

27

Qo

 

 

 

28060

23850

19920

16290

12740

9780

7360

Pe

 

 

 

13.01

11.52

10.09

8.85

7.55

6.37

5.29

32

Qo

 

 

 

25730

21860

17850

14540

11570

8890

6530

Pe

 

 

 

13.41

11.82

10.29

8.86

7.56

6.31

5.14

43

Qo

 

 

 

 

 

 

11740

9190

6880

4840

Pe

 

 

 

 

 

 

9.07

7.56

6.17

5.07

BFB-FJZ-

V20HPHY

27

Qo

49770

43410

35810

28880

24460

20410

16550

13340

10210

7370

Pe

16.12

14.79

13.47

12.19

10.92

9.69

8.48

7.31

6.19

5.11

32

Qo

46610

40940

33600

27160

23880

18860

14990

11980

9280

6810

Pe

16.79

15.36

13.92

12.53

11.16

8.84

8.56

7.32

6.19

5.05

43

Qo

 

 

 

 

 

15440

12220

9350

6850

4680

Pe

 

 

 

 

 

10.01

8.63

7.16

5.91

4.67

 

Note: The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

 

SEMI-HERMETIC COMPRESSOR & AIR-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-FJZ-

V15HPY

27

Qo

 

 

 

36730

30960

26210

26860

16880

13500

10390

Pe

 

 

 

18.54

16.00

13.99

12.29

10.57

8.99

7.34

32

Qo

 

 

 

35560

29050

24060

18910

15440

12290

9330

Qo

 

 

 

19.67

16.78

14.62

12.77

10.84

9.20

7.54

43

Pe

 

 

 

 

 

 

16470

13130

10290

8520

Qo

 

 

 

 

 

 

12.95

11.06

9.38

7.69

BFB-FJZ-

V25HPHY

27

Qo

61980

52530

45040

38250

31690

25920

20990

16690

13170

9520

Pe

21.98

20.27

18.24

16.48

14.80

13.22

11.70

10.03

8.45

6.88

32

Qo

59050

49940

42950

36500

30340

24090

19270

15430

12300

9230

Qo

23.14

21.29

19.00

17.23

16.19

13.51

11.64

9.89

8.24

6.67

43

Pe

 

 

 

 

 

 

16660

13100

10150

8430

Qo

 

 

 

 

 

 

12.13

10.31

8.51

6.81

BFB-FJZ-

V20HPY

27

Qo

 

 

 

43540

36070

29700

24220

19710

15870

12300

Pe

 

 

 

20.90

18.10

15.86

13.90

12.08

10.20

8.33

32

Qo

 

 

 

41650

34170

27970

22770

18760

15150

11660

Pe

 

 

 

22.04

18.97

16.64

14.60

12.57

10.61

8.59

43

Qo

 

 

 

 

 

 

19840

15950

12630

10650

Pe

 

 

 

 

 

 

14.80

12.80

10.82

8.77

BFB-FJZ-

W25HPY

27

Qo

 

 

 

51690

44860

38170

31760

25740

20350

15500

Pe

 

 

 

28.15

24.71

21.53

18.55

15.81

13.27

10.91

32

Qo

 

 

 

49050

41100

35040

29180

23660

18580

14030

Pe

 

 

 

29.57

25.43

22.15

19.03

16.13

13.43

10.97

43

Qo

 

 

 

 

 

 

24720

19620

15080

11100

Pe

 

 

 

 

 

 

19.31

16.46

13.51

11.04

BFB-FJZ-

V30HPHY

27

Qo

70790

59870

51540

43890

36450

29470

24090

19420

15940

12400

Pe

25.29

22.99

20.58

18.56

16.70

14.95

13.27

11.37

9.70

8.04

32

Qo

67650

57240

49350

41980

34980

28300

23160

18700

15380

11760

Pe

26.16

24.04

21.56

19.47

17.54

15.40

13.40

11.48

9.80

8.12

43

Qo

 

 

 

 

 

 

19860

15880

12690

10700

Pe

 

 

 

 

 

 

14.01

11.96

10.09

8.22

BFB-FJZ-

W30HPY

27

Qo

 

 

 

63940

54080

45160

36770

29850

24080

18630

Pe

 

 

 

31.04

26.77

23.50

20.69

17.89

15.21

12.33

32

Qo

 

 

 

61260

51330

42410

34590

28400

21070

17740

Pe

 

 

 

32.69

28.11

24.72

21.77

18.58

15.93

12.86

43

Qo

 

 

 

 

 

 

29300

23550

18650

14040

Pe

 

 

 

 

 

 

22.08

18.96

16.01

12.99

BFB-FJZ-

W35HPHY

27

Qo

85830

72600

62290

52520

45210

38940

33340

26090

20580

15680

Pe

34.14

30.87

27.81

25.07

22.84

20.29

17.66

14.94

12.57

10.57

32

Qo

81140

68840

58540

49460

41990

35620

29780

24090

18740

14230

Pe

35.38

32.49

29.19

26.53

23.81

20.81

18.07

15.81

12.87

10.77

43

Qo

 

 

 

 

 

 

25180

19780

15270

11270

Pe

 

 

 

 

 

 

18.36

16.16

13.17

10.82

BFB-FJZ-

W40HPHY

27

Qo

106180

89810

77060

64970

54500

46070

38600

30260

24360

18850

Pe

37.55

33.98

30.57

27.57

24.75

22.15

19.70

16.91

14.41

11.93

32

Qo

101350

85990

73130

61780

52440

43110

35300

28920

22170

17990

Pe

39.08

35.89

32.24

29.30

26.32

23.19

20.13

18.20

15.27

12.62

43

Qo

 

 

 

 

 

 

29850

23740

18890

14250

Pe

 

 

 

 

 

 

20.77

18.62

15.61

12.74

BFB-FJZ-

W40HPY

27

Qo

 

 

 

76400

64570

53810

43680

35440

28400

21880

Pe

 

 

 

37.25

32.13

28.10

24.65

21.17

17.96

14.50

32

Qo

 

 

 

73080

61170

50520

41060

33740

27110

20750

Pe

 

 

 

39.28

33.67

29.49

25.88

22.02

18.68

14.95

43

Qo

 

 

 

 

 

 

34760

27810

21920

16360

Pe

 

 

 

 

 

 

26.24

22.37

18.79

15.60

BFB-FJZ-

W50HPHY

27

Qo

127010

107360

92040

77410

65010

54890

44690

35940

28840

22070

Pe

47.01

42.40

38.08

34.43

30.99

27.77

24.70

21.28

18.02

14.72

32

Qo

121360

102640

87200

74190

62390

51210

41880

34140

27360

20970

Pe

48.64

44.33

39.90

36.11

32.54

28.61

24.94

21.49

18.21

14.82

43

Qo

 

 

 

 

 

 

35460

28020

22210

16620

Pe

 

 

 

 

 

 

25.71

21.97

18.36

15.13

 

Note: The refrigerating effect is got on the basis of suction temperature 20℃ and liquid with over-cold.

 

SEMI - HERMETIC COMPRESSOR & WATER-COOLED CONDENSING UNIT CAPACITY

R22 Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
12.5 10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-WJZ-

3HP

40

Qo

 

 

 

 

 

7360

5800

4520

3360

2590

 

BFB-WJZ-

4HPH

40

Qo

 

 

 

 

 

9150

7230

5670

4230

3300

 

BFB-WJZ-

4HPH

40

Qo

 

 

14440

13180

10760

9150

7230

5670

4230

3300

 

BFB-WJZ-

5HP

40

Qo

 

 

 

 

 

11690

9550

7580

6020

3300

 

BFB-WJZ-

5HPH

40

Qo

22700

20810

19010

17360

14710

11690

9550

7580

6020

4520

 

BFB-WJZ-

8HPH

40

Qo

 

 

27870

25450

20820

16880

13410

10440

8210

4520

 

BFB-WJZ-

10HP

40

Qo

 

 

 

 

 

23610

19320

15270

12040

6200

 

BFB-WJZ-

10HPH

40

Qo

44390

40720

37190

33970

28760

23610

19320

15270

12040

9110

 

BFB-WJZ-

15HP

40

Qo

 

 

 

 

 

34710

28120

22440

17710

9110

 

BFB-WJZ-

15HPH

40

Qo

65440

61020

55680

49510

42340

35280

28450

22660

17670

13360

 

BFB-WJZ-

V3HP

40

Qo

 

 

 

 

 

11000

8850

7010

5890

4560

3460

BFB-WJZ-

V5HPH

40

Qo

21150

19360

17710

16150

13470

11010

8860

7010

5420

4050

2940

BFB-WJZ-

V4HP

40

Qo

 

 

 

 

 

13560

10960

8700

7400

5740

4350

BFB-WJZ-

V6HPH

40

Qo

26220

24100

21950

20040

16590

13570

10970

8710

6770

5110

3730

BFB-WJZ-

V5HP

40

Qo

 

 

 

 

 

16330

13190

10480

8650

6740

5120

BFB-WJZ-

V7HPH

40

Qo

31530

28860

26390

24110

20140

16330

13190

10480

8150

6210

4500

BFB-WJZ-

V6HP

40

Qo

 

 

 

 

 

19650

16080

12820

10020

7620

5650

BFB-WJZ-

V9HPH

40

Qo

37740

34580

31640

28960

23980

19650

16080

12830

10030

7630

5660

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and the degree of supercooling 5℃.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI-HERMETIC COMPRESSOR & WATER-COOLED CONDENSING UNIT CAPACITY

R22  Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)   Power Consumption Pe(kw)
Evaporating temperature(℃)
12.5 10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-WJZ-

V8HP

40

Qo

 

 

 

 

 

26390

21490

17310

13870

10780

8040

BFB-WJZ-

V12HPH

40

Qo

50120

45250

41470

37930

31580

26260

21190

17040

13570

10470

7820

BFB-WJZ-

V10HP

40

Qo

 

 

 

 

 

30520

24940

20120

16060

12460

9310

BFB-WJZ-

V15HPH

40

Qo

59690

54230

50180

45410

37680

30990

25220

20130

16030

12300

9130

BFB-WJZ-

V12HP

40

Qo

 

 

 

 

 

35550

29060

23430

18600

14470

10710

BFB-WJZ-

V20HPH

40

Qo

68480

62760

57520

52570

43650

35890

29150

24050

18340

14070

10430

BFB-WJZ-

V15HP

40

Qo

 

 

 

 

 

45210

34500

29440

23210

17860

13350

BFB-WJZ-

V25HPH

40

Qo

86570

79430

72770

66500

55300

45500

37010

29730

23400

18020

13450

BFB-WJZ-

V20HP

40

Qo

 

 

 

 

 

51960

40280

34060

26770

20530

15700

BFB-WJZ-

W25HP

40

Qo

 

 

 

 

 

68340

55770

44700

35240

26920

20030

BFB-WJZ-

W30HP

40

Qo

 

 

 

 

 

77950

63520

51100

40410

31040

23110

BFB-WJZ-

V30HPH

40

Qo

98580

90460

82920

75860

63060

52260

40480

34360

27170

20930

15900

BFB-WJZ-

W35HPH

40

Qo

129490

118930

109020

99800

83080

68820

56050

45050

35580

27180

20150

BFB-WJZ-

W40HPH

40

Qo

147960

135830

124460

113770

94650

77950

63520

51100

40410

31330

23690

BFB-WJZ-

W40HP

40

Qo

 

 

 

 

 

92170

76260

60750

48230

37150

17890

BFB-WJZ-

W50HPH

40

Qo

173900

159700

146430

134010

111660

92370

76460

60850

48430

37350

27990

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and the degree of supercooling 5℃

2. If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI-HERMETIC COMPRESSOR & WATER-COOLED CONDENSING UNIT CAPACITY

R134a Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)   Power Consumption Pe(kw)
Evaporating temperature(℃)
12.5 10 7.5 5 0 -5 -10 -15 -20 -25 -30

BFB-WJZ-

3HPY

40

Qo

9940

9000

8010

7350

6140

4810

3870

2900

1910

1400

930

BFB-WJZ-

4HPY

40

Qo

11080

10090

9160

8290

6670

5670

4320

3310

2240

1580

1080

BFB-WJZ-

5HPY

40

Qo

14590

13290

12060

10920

9120

7133

5710

4450

3190

2290

1510

BFB-WJZ-

8HPHY

40

Qo

21330

19440

16750

14000

12917

10300

8010

6130

4350

3150

 

BFB-WJZ-

10HPY

40

Qo

28550

26020

23590

21300

17850

14400

11560

8970

6380

4640

 

BFB-WJZ-

15HPY

40

Qo

42080

38350

24780

31430

26280

21120

16820

13180

9400

6800

4800

BFB-WJZ-

V3HPY

40

Qo

13790

12530

11380

10300

8370

6720

5310

4110

3100

2240

1560

BFB-WJZ-

V4HPY

40

Qo

17850

16220

14720

13330

10840

8720

6910

5380

4110

3040

2160

BFB-WJZ-

V5HPY

40

Qo

21270

19360

17580

15950

13010

10480

8310

6480

4930

3640

2580

BFB-WJZ-

V6HPY

40

Qo

25480

23180

21070

19100

15590

12570

10010

7820

5980

4430

3150

BFB-WJZ-

V8HPY

40

Qo

33270

30280

27490

24890

20290

16340

12960

10080

7650

5620

3910

BFB-WJZ-

V10HPY

40

Qo

38810

35280

32050

29060

23670

19020

15050

11680

8820

6410

4390

BFB-WJZ-

V12HPY

40

Qo

44390

40380

36700

33270

26310

21850

17330

13480

10230

7500

5220

BFB-WJZ-

V15HPY

40

Qo

59460

54030

48890

44230

35890

28710

22650

17560

13290

9760

6870

BFB-WJZ-

V20HPY

40

Qo

66570

61430

54830

49580

40210

32230

25450

19770

14990

11040

7820

BFB-WJZ-

W25HPY

40

Qo

88780

80680

73050

66100

53560

42900

33870

26200

19830

14570

10260

BFB-WJZ-

W30HPY

40

Qo

99920

90740

82250

74410

60370

48430

38210

29660

22500

16590

11730

BFB-WJZ-

W40HPY

40

Qo

117390

106690

96760

87590

71160

57210

45270

35240

26880

19920

14220

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and the degree of supercooling 5℃.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI·HERMETIC COMPRESSOR & WATER-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)   Power Consumption Pe(kw)
Evaporating temperature(℃)
7.5 5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-WJZ-

3HPHY

40

Qo

 

 

 

8160

6480

5120

3870

3040

2200

1590

1080

BFB-WJZ-

4HPHY

40

Qo

 

 

 

9470

8040

6010

4550

3630

2530

1650

1280

BFB-WJZ-

4HPHY

40

Qo

14680

13440

11050

9470

8040

6010

4550

3630

2530

1650

1280

BFB-WJZ-

5HPY

40

Qo

 

 

 

12100

9980

8000

6480

4970

3590

2600

1770

BFB-WJZ-

5HPHY

40

Qo

19330

17700

15100

12100

9980

8000

6480

4970

3590

2600

1770

BFB-WJZ-

8HPHY

40

Qo

 

25950

21390

17480

14000

11080

8830

6820

5260

3810

2600

BFB-WJZ-

10HPY

40

Qo

 

 

 

24640

20490

16300

12960

10240

7390

5700

3920

BFB-WJZ-

10HPHY

40

Qo

37810

34630

29540

24440

20190

16200

12860

10040

7730

5600

3820

BFB-WJZ-

15HPY

40

Qo

 

 

 

35420

28300

23000

18970

14680

11180

8080

5360

BFB-WJZ-

15HPHY

40

Qo

55740

51000

43490

35220

28100

22800

18870

14580

11080

8070

5280

BFB-WJZ-

V3HPY

40

Qo

 

 

 

11500

9470

7700

6170

4860

3730

2770

1970

BFB-WJZ-

V5HPHY

40

Qo

18150

16650

13950

11590

9530

7750

6210

4870

3740

2780

1960

BFB-WJZ-

V4HPY

40

Qo

 

 

 

14370

11810

9600

7680

6040

4630

3430

2420

BFB-WJZ-

V6HPHY

40

Qo

23030

21140

17690

14670

12060

9790

7820

6130

4670

3450

2410

BFB-WJZ-

V5HPY

40

Qo

 

 

 

17560

14450

11750

9410

7400

5690

4230

3000

BFB-WJZ-

V7HPHY

40

Qo

27360

25070

20990

17400

14280

11570

9220

7210

5480

4020

2790

BFB-WJZ-

V6HPY

40

Qo

 

 

 

21000

17330

14130

11360

8980

6940

5210

3750

BFB-WJZ-

V9HPHY

40

Qo

32690

30000

25170

20990

17320

14120

11370

8990

6960

5220

3750

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and the degree of supercooling 5℃.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

SEMI · HERMETIC COMPRESSOR & WATER-COOLED CONDENSING UNIT CAPACITY

R404A Watt(50Hz 380v)

 

Model

Condensing

temperature(℃)

Capacity Qo(kw)  Power Consumption Pe(kw)
Evaporating temperature(℃)
7.5 5 0 -5 -10 -15 -20 -25 -30 -35 -40

BFB-WJZ-

V8HPY

40

Qo

 

 

 

27610

22680

18380

14690

11500

8780

6490

4560

BFB-WJZ-

V12HPY

40

Qo

43280

39650

33130

27410

22490

18170

14460

11260

8550

6240

4300

BFB-WJZ-

V10HPHY

40

Qo

 

 

 

32140

26370

21390

17040

13330

10170

7480

5210

BFB-WJZ-

V15HPY

40

Qo

51940

47610

39750

32880

26910

21740

17270

13420

10140

7350

4990

BFB-WJZ-

V12HPY

40

Qo

 

 

 

37280

30540

24550

19610

15360

11720

8650

6060

BFB-WJZ-

V20HPHY

40

Qo

60200

55300

46100

38100

30310

24440

19580

15040

11330

8300

5570

BFB-WJZ-

V15HPY

40

Qo

 

 

 

48110

39720

32430

26160

20760

16150

12220

8920

BFB-WJZ-

V25HPHY

40

Qo

74700

68530

57430

47680

39230

30850

25530

20080

15370

11390

8030

BFB-WJZ-

V20HPY

40

Qo

 

 

 

53170

47000

37780

30240

24000

18850

14350

10540

BFB-WJZ-

W25HPY

40

Qo

 

 

 

72090

59450

48440

39190

30950

23960

18220

13300

BFB-WJZ-

V30HPHY

40

Qo

85310

78260

65460

52550

44970

36630

29000

23000

17890

13790

7970

BFB-WJZ-

W30HPY

40

Qo

 

 

 

83680

69150

56650

45850

36590

28560

21780

15980

BFB-WJZ-

W35HPHY

40

Qo

112230

102870

86180

71500

59070

47960

38420

30180

23200

17320

12360

BFB-WJZ-

W40HPHY

40

Qo

12800C

117390

89240

81480

67420

54820

44080

34960

27120

20540

15000

BFB-WJZ-

W40HPY

40

Qo

 

 

 

99910

82620

67630

54630

43460

33900

25690

18760

BFB-WJZ-

W50HPHY

40

Qo

153120

140400

117390

100190

82820

67730

54830

43560

34100

25790

18860

 

Note:

1.The refrigerating effect is got on the basis of suction temperature 20℃ and the degree of supercooling 5℃.

2.If the service temperature is very low, a cooling spray system should be equiped. For the details please refer to the compressor instructions.

 

OVERALL DIMENSION OF AIR-COOLED CONDENSING UNIT

 

 

TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR AIR-COOLED CONDENSING UNIT

 

Unit model

Dimension ( mm )

Outlet diameter(mm) 

Inlet diameter(mm) 

A

B

D

E

H

L

BFB-FJZ-3HP(Y)

720

520

133

480

739

780

12

19.5

BFB-FJZ-4HP(Y)

885

520

159

487

810

780

12

25

BFB-FJZ-4HPH(Y)

885

520

159

487

810

780

12

25

BFB-FJZ_5HP(Y)

885

520

159

487

810

780

12

25

BFB-FJZ-5HPH(Y)

885

520

159

487

810

780

12

25

BFB-FJZ-8HPH(Y)

980

840

180

455

965

930

16

25

BFB-FJZ-IOHP(Y)

1280

1120

159

455

965

930

16

31.75

BFB-FJZ-IOHPH(Y)

1280

1120

159

455

965

930

16

31.75

BFB_FJZ_15HP(Y)

1470

1100

180

455

965

950

16

31.75

BFB_FJZ_15HPH(Y)

1470

1100

180

455

965

950

16

38

 

BFB-FJZ-V3HP(Y)~BFB-FJZ-V7HPH(Y),BFB-FJZ-V9HPH(Y)

 

 

BFB-FJZ-V8HP(Y),BFB-FJZ-V10HP(Y)〜BFB-FJZ-V15HPH(Y)

 

BFB-FJZ-V20HPH(Y)

 

NEW TYPE TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR AIR-COOLED CONDENSING UNIT

 

Unit model

Dimension ( mm )

Mounting Dimension(mm)

Outlet diameter(mm)

Inlet diameter(mm)

A

L

H

B

E

BFB-FJZ-V3HP (Y)

890

850

815

683

375

Φ12

Φ22

BFB-FJZ-V5HPH (Y)

890

850

815

683

375

Φ12

Φ22

BFB-FJZ-V4HP (Y)

890

850

815

683

375

Φ12

Φ28

BFB-FJZ-V6HPH (Y)

910

1010

1065

683

375

Φ12

Φ28

BFB-FJZ-V5HP (Y)

890

850

815

683

375

Φ12

Φ28

BFB-FJZ-V7HPH (Y)

1000

1070

1065

1103

435

Φ16

Φ28

BFB-FJZ-V6HP (Y)

930

1010

875

683

375

Φ16

Φ28

BFB-FJZ-V9HPH (Y)

1000

1070

1035

1103

435

Φ16

Φ28

BFB-FJZ-V8HP (Y)

1280

1070

980

1103

455

Φ16

Φ35

BFB-FJZ-V12HPH (Y)

1280

1070

980

1103

455

Φ16

Φ35

BFB-FJZ-V10HP (Y)

1280

1070

980

1103

455

Φ16

Φ35

BFB-FJZ-V15HPH (Y)

1450

1000

1045

1103

455

Φ16

Φ42

BFB-FJZ-V12HP (Y)

1450

1070

980

1103

455

Φ16

Φ35

BFB-FJZ-V20HPH (Y)

1770

1180

1100

1594

1130

Φ22

Φ42

 

 

NEW TYPE TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR AIR-COOLED CONDENSING UNIT

 

 

Unit model

Dimension(mm)

Mounting

Dimenson(mm)

Outlet diameter(mm)

Inlet diameter(mm)

A

L

H

B

E

B-FJZ-V15HP(Y)

1450

1120

1050

1274

1070

0Φ22

Φ42

B-FJZ-V25HP(Y)

1770

1180

1100

797×797

1130

Φ22

Φ42

B-FJZ-V20HP

1640

1180

1000

1464

1130

Φ22

Φ42

B-FJZ-V30HPH

1650

1270

1400

762×762

1220

Φ22

Φ42

B-FJZ-W25HP

1770

1180

1100

797×797

1130

Φ22

Φ42

B-FJZ-W35HPH

1650

1270

1600

762×762

1220

Φ28

Φ42

B-FJZ-W30HP

1650

1270

1400

762×762

1220

Φ22

Φ42

B-FJZ-W40HPH

1850

1180

1600

837×837

1130

Φ28

Φ54

B-FJZ-W40HP

1650

1270

1500

762×762

1220

Φ28

Φ54

B-FJZ-W50HPH

2130

1180

1800

977×977

1130

Φ28

Φ54

 

OVERALL DIMENSION OF WATER-COOLED CONDENSING UNIT

 

BFB-WJZ-3HP(Y)~BFB-WJZ-15HPH(Y)

 

 

TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR WATER-COOLED CONDENSING UNIT

 

Unit model

Dimension ( mm )

Outlet diameter(mm)

Inlet diameter(mm)

A

B

C

D

H

L

E

BFB-WJZ-3HP(Y)

906

550

450

168

585

370

330

12

19.5

BFB-WJZ-4HPH(Y)

1030

690

480

219

720

370

330

12

25

BFB-WJZ-4HPH(Y)

1030

690

480

219

720

370

330

12

25

BFB-WJZ-5HP(Y)

1030

690

480

219

720

370

330

12

25

BFB-WJZ-5HPH(Y)

1030

690

480

219

720

370

330

12

25

BFB-WJZ-8HPH(Y)

1180

780

480

219

800

370

330

16

31.75

BFB-WJZ-IOHP(Y)

1230

780

480

219

800

370

330

16

31.75

BFB-WJZ-IOHPH(Y)

1230

780

480

219

800

370

330

16

31.75

BFB-WJZ-15HP(Y)

1230

890

500

273

800

440

400

16

38

BFB-WJZ-15HPH(Y)

1230

890

500

273

800

440

400

16

38

 

OVERALL DIMENSION OF WATER-COOLED CONDENSING UNIT

 

 

TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR WATER-COOLED CONDENSING UNIT

 

Unit model

Dimension ( mm )

Outlet diameter(mm)

Inlet diameter(mm)

A

B

E

H

L

BFB-WJZ-V3HP(Y)

1056

690

330

738

480

Φ12

Φ22

BFB-WJZ-V5HPH(Y)

1056

690

330

738

480

Φ12

Φ22

BFB-WJZ-V4HP(Y)

1056

690

330

738

480

Φ12

Φ28

BFB-WJZ-V6HPH(Y)

1206

780

330

738

480

Φ12

Φ28

BFB-WJZ-V5HP(Y)

1056

690

330

738

480

Φ12

Φ28

BFB-WJZ-V7HPH(Y)

1206

780

330

738

480

Φ16

Φ28

BFB-WJZ-V6HP(Y)

1206

780

330

738

480

Φ16

Φ28

BFB-WJZ-V9HPH(Y)

1206

780

330

738

480

Φ16

Φ28

BFB-WJZ-V8HP(Y)

1206

780

330

740

650

Φ16

Φ35

BFB-WJZ-V12HPH(Y)

1246

890

400

805

650

Φ16

Φ35

BFB-WJZ-VIOHP(Y)

1246

890

400

805

650

Φ16

Φ35

BFB-WJZ-V15HPH(Y)

1356

900

400

805

650

Φ16

Φ42

BFB-WJZ-V12HP(Y)

1246

890

400

805

650

Φ16

Φ35

BFB-WJZ-V20HPH(Y)

1356

900

400

805

650

Φ22

Φ42

 

BFB-WJZ-V15HP(Y)~BFB-WJZ-W50HPH(Y)

 

 

TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR WATER-COOLED CONDENSING UNIT

 

Unit model

Dimension ( mm )

Outlet diameter(mm)

Inlet diameter(mm)

A

B

C

D

H

L

E

BFB-WJZ-V15HP(Y)

1380

900

650

273

950

440

400

22

42

BFB-WJZ-V25HPH(Y)

1735

1200

700

273

1000

440

400

22

42

BFB-WJZ-V20HP(Y)

1380

900

650

273

950

440

400

22

42

BFB-WJZ-W25HP(Y)

1735

1200

700

273

1000

440

400

22

42

BFB-WJZ-V30HPH(Y)

1735

1200

650

273

950

440

400

22

42

BFB-WJZ-W30HP(Y)

1735

1200

700

273

1000

440

400

22

42

BFB-WJZ-W35HPH(Y)

1735

1200

700

273

1000

440

400

28

42

BFB-WJZ-W40HPH(Y)

1735

1200

700

273

1000

440

400

28

54

BFB-WJZ-W40HP(Y)

1735

1200

700

273

1000

440

400

28

54

BFB-WJZ-W50HPH(Y)

2165

1430

700

273

1000

440

400

28

54

 

OVERALL DIMENSION OF PARALLEL WATER-COOLED CONDENSING UNIT

 

BFB-WJZ80HP(2)(Y)~BFB-WJZ200HPH(4)(Y)  Parallel unit

 

TABLE OF UNIT OVERALL DIMENTION FOR SEMI-HERMETIC COMPRESSOR WATER-COOLED CONDENSING PARALLEL UNIT

 

Unit model

Dimension ( mm )

Outlet diameter Φmm

Inlet diameter Φmm

A

B

C

D

H

E

L

BFB-WJZ-80HP(2)(Y)

2000

1880

900

Φ325

1980

950

1000

Φ35

Φ76

BFB-WJZ_90HPH(3)(Y)

2260

2160

850

Φ325

1700

900

950

Φ35

Φ89

BFB-WJZ-120HP(3)(Y)

2712

2595

900

Φ325

1750

950

1000

Φ42

Φ108

BFB-WJZ-200HPH(4)(Y)

3470

3307

1000

Φ426

2100

1050

1100

Φ54

Φ108

 

Note: other requirements for unit, is can as custormer application and we can do special order make. The unit refrigeration quantity is the corresponding single plane multiple.

 

SEMI · HERMETIC AIR-COOLED UNIT CONDENSER CONFIGURATION TABLE

 

Unit model

Compressor

air-cooled condenser

receiver

Inlet

diameter Φ mm

Outlet

diameter Φmm

Model

Power Source

Power KW

Model

fan

Volume L

Power Source

Power KW

BFB-FJZ-3HP(Y)

BFBZ3 12(Y)

Power 380V/3~/50Hz

Control220/1~50Hz (460/3~/60Hz)

2.2

BF-FNK03S

 

 

 

 

 

 

380V/3~/50Hz(460/3~/60Hz)

 

 

 

 

 

 

 

0.18

7

19.5

12

BFB-FJZ-4HP(Y)

BFBZ4 15(Y)

2.2

BF-FNK04S

0.25

9.5

25

12

BFB-FJZ-4HPH(Y)

BFBZ4 15H(Y)

3

BF-FNK04SH

0.25

9.5

25

12

BFB-FJZ-5HP(Y)

BFBZ5 18(Y)

3.7

BF-FNK05S

0.25

9.5

25

12

BFB-FJZ-5HPH(Y)

BFBZ5 18H(Y)

5.1

BF-FNK05SH

0.25

9.5

25

12

BFB-FJZ-8HPH(Y)

BFBZ8 27H(Y)

5.5

BF-FNK08S

0.37

15

31.75

16

BFB-FJZ-10HP(Y)

BFBZ10 36(Y)

7.5

BF-FNK10S

0.5

19.5

31.75

16

BFB-FJZ-10HPH(Y)

BFBZ10 36H(Y)

9.6

BF-FNK10SH

0.5

19.5

31.75

16

BFB-FJZ-15HP(Y)

BFBZ1554(Y)

10.5

BF-FNK15S

0.74

28

38

16

BFB-FJZ-15HPH(Y)

BFBZ1554H(Y)

12

BF-FNK15SH

0.74

28

38

16

BFB-FJZ_V3HP(Y)

BFBV318.1(Y)

2.2

BF-FNK04S

0.25

15

22

12

BFB-FJZ-V5HPH(Y)

BFBV5 18.2H(Y)

3

BF-FNK05S

0.25

15

22

12

BFB-FJZ_V4HP(Y)

BFBV4 22.7(Y)

3

BF-FNK05S

0.25

15

28

12

BFB-FJZ-V6HPH(Y)

BFBV6 22.7H(Y)

3.7

BF-FNK05S

0.37

15

28

12

BFB-FJZ_V5HP(Y)

BFBV5 26.8(Y)

3.7

BF-FNK05S

0.37

15

28

12

BFB-FJZ-V7HPH(Y)

BFBV7 26.8H(Y)

5.1

BF-FNK08SH

0.37

19.5

28

16

BFB-FJZ_V6HP(Y)

BFBV6 32.5(Y)

4.5

BF-FNK05SH

0.25

15

28

16

BFB-FJZ-V9HPH(Y)

BFBV9 32.5H(Y)

5.5

BF-FNK10S

0.25

19.5

28

16

BFB-FJZ-V8HP(Y)

BFBV8 41.3(Y)

5.5

BF-FNK10S

0.25

22

35

16

BFB-FJZ-V12HPH(Y)

BFBV1241.3H(Y)

8.8

BF-FNK10SH

0.25

22

35

16

BFB-FJZ-VIOHP(Y)

BFBV1048.5(Y)

7.4

BF-FNK10S

0.25

22

35

16

BFB-FJZ-V15HPH(Y)

BFBV1548.5H(Y)

11

BF-FNK18SH

0.37

28

42

16

BFB-FJZ-V12HP(Y)

BFBV1256(Y)

9.1

BF-FNK15S

0.37

22

35

16

BFB-FJZ-V20HPH(Y)

BFBV2056H(Y)

15

BF-FNK-20SH

0.78

28

42

22

BFB-FJZ-V15HP(Y)

BFBV1573.7(Y)

11

BF-FNK-15SH

0.6

38

42

22

BFB-FJZ-V25HPH(Y)

BFBV2573.7H(Y)

18

BF-FNK-15ST

0.8

38

42

22

BFB-FJZ-V20HP(Y)

BFBV20 84.5(Y)

15

BF-FNK-20S

0.78

38

42

22

BFB-FJZ-V30HPH(Y)

BFBV30 84.5H(Y)

22

BF-FNK-30S

0.45

38

42

22

BFB-FJZ-W25HP(Y)

BFBW25110_5(Y)

18

BF-FNK-25S

0.8

38

42

22

BFB-FJZ-W35HPH(Y)

BFBW35110.5H(Y)

27

BF-FNK-30SH

0.6

38

42

28

BFB_FJZ-W30HP(Y)

BFBW30 126_8(Y)

22

BF-FNK-30S

0.45

38

42

22

BFB-FJZ-W40HPH(Y)

BFBW40 126.8H(Y)

30

BF-FNK-40S

0.6

75

54

28

BFB_FJZ-W40HP(Y)

BFBW40151.6(Y)

30

BF-FNK-35S

0.45

75

54

28

BFB-FJZ-W50HPH(Y)

BFBW50151.6H(Y)

37

BF-FNK-50S

0.78

75

54

28

 

SEMI · HERMETIC WATER-COOLED UNIT CONDENSER CONFIGURATION TABLE

 

Unit model

Compressor

water-cooled condenser

Inlet diameter Φ mm

Outlet diameter Φ mm

Model

Power Source

Power KW

Model

Water pipe in

BFB-WJZ-3HP(Y)

BFBZ3 12(Y)

Power 38V/3~/50Hz

Control220/1~50Hz (460/3~/60Hz)

2.2

BF-WN-3HP

1

19.5

12

BFB-WJZ-4HP(Y)

BFBZ4 15(Y)

2.2

BF-WN-4HP

1

25

12

BFB-WJZ-4HPH(Y)

BFBZ4 15H(Y)

3

BF-WN-4HPA①

1-1/4

25

12

BFB-WJZ-5HP(Y)

BFBZ5 18(Y)

3.7

BF-WN-5HP

1-1/2

25

12

BFB-WJZ-5HPH(Y)

BFBZ5 18H(Y)

5.1

BF-WN-5HP A①

1-1/2

258

12

BFB-WJZ_8HPH(Y)

BFBZ8 27(Y)

5.5

BF-WN-8HP

1-1/2

31.75

16

BFB-WJZ-IOHP(Y)

BFBZ10 36(Y)

7.5

BF-WN-10HP

1-1/2

31.75

16

BFB-WJZ-IOHPH(Y)

BFBZ10 36H(Y)

9.6

BF-WN-10HP A①

1-1/2

31.75

16

BFB-WJZ-15HP(Y)

BFBZ15 54(Y)

10.5

BF-WN-15HP

1-1/2

38

16

BFB-WJZ-15HPH(Y)

BFBZ15 54H(Y)

12

BF-WN-15HP A①

1-1/2

38

16

BFB-WJZ-V3HP(Y)

BFBV3 18.1(Y)

2.2

BF-WN-4HP High

1-1/2

22

12

BFB-WJZ-V5HPH(Y)

BFBV518.1H(Y)

3

BF-WN-5HP High

1-1/2

22

12

BFB-WJZ-V4HP(Y)

BFBV4 22.7(Y)

3

BF-WN-5HP Medium

1-1/2

28

12

BFB-WJZ-V6HPH(Y)

BFBV6 22.7H(Y)

3.7

BF-WN-8HP Medium

1-1/2

28

12

BFB-WJZ-V5HP(Y)

BFBV5 26.8(Y)

3.7

BF-WN-5HP Medium

1-1/2

28

12

BFB-WJZ-V7HP(Y)

BFBV7 26.8H(Y)

5.1

BF-WN-8HP High

1-1/2

28

16

BFB-WJZ-V6HP(Y)

BFBV6 32.5(Y)

4.5

BF-WN-8HP Medium

1-1/2

28

16

BFB-WJZ-V9HPH(Y)

BFBV9 32.5H(Y)

5.5

BF-WN-10HP High

1-1/2

28

16

BFB-WJZ-V8HP(Y)

BFBV8 41.3(Y)

5.5

BF-WN-10HP High

1-1/2

35

16

BFB-WJZ-V12HPH(Y)

BFBV12 41.3H(Y)

8.8

BF-WN-15HP High

1-1/2

35

16

BFB-WJZ-VIOHP(Y)

BFBV10 48.5(Y)

7.4

BF-WN-15HP Medium

1-1/2

35

16

BFB-WJZ-V15HPH(Y)

BFBV15 48.5H(Y)

11

BF-WN-20HP Medium

2-1/2

42

16

BFB-WJZ-V12HP(Y)

BFBV12 56(Y)

9.1

BF-WN-15HP High

1-1/2

35

16

BFB-WJZ-V20HPH(Y)

BFBV20 56(Y)

15

BF-WN-20HP High

2-1/2

42

22

BFB-WJZ-V15HP(Y)

BFBV15 73.7(Y)

11

BF-WN-20HP High

2-1/2

42

22

BFB-WJZ-V25HPH(Y)

BFBV25 73.7H(Y)

18

BF-WN-30HP High

2-1/2

42

22

BFB-WFJZ-V20HP(Y)

BFBV20 84.5(Y)

15

BF-WN-20HP

2-1/2

42

12

BFB-WFJZ-W25HP(Y)

BFBW25110.5(Y)

18

BF-WN-25HP

2-1/2

54

22

BFB-WFJZ-V30HPH(Y)

BFBV30 84.5H(Y)

22

BF-WN-30HP

2-1/2

54

22

BFB-WFJZ-W30HP(Y)

BFBW30126.8(Y)

22

BF-WN-30HP

2-1/2

54

22

BFB-WFJZ-W35HPH(Y)

BFBW35110.5H(Y)

27

BF-WN-35HP

2-1/2

54

28

BFB-WFJZ-W40HPH(Y)

BFBW40126.8H(Y)

30

BF-WN-40HP

2-1/2

54

28

BFB-WFJZ-W40HP(Y)

BFBW40151.6(Y)

30

BF-WN-40HP

2-1/2

54

28

BFB-WFJZ-W50HPH(Y)

BFBW50151.6H(Y)

37

BF-WN-50HP

2-1/2

54

28

BFB-WFJZ-W80HPH(Y)

BFBW40151.6x2

30x2

BF-WN-75HP

3"

76

35

BFB-WFJZ-W90HPH(Y)

BFBV30 84.5Hx3

22x3

90 RT

4"

89

35

BFB-WFJZ-W120HPH(Y)

BFBW40151.6x3

30x3

110RT

4"

108

42

BFB-WFJZ-W200HPH(Y)

BFBW50151.6Hx4

37x4

170RT

Dn150

108

54

 

Notes:

1) With A means it is the new model of expand heat exchage area.

2) In advance fill polyester oil and then charing R134 aor R404A,The fither screen use XH-10 or XH11,after recharing refrigreant that

should be same type.

3) The peformance data of paralley unit,which is same as two times single compressor.if you need the deatil information,please contact us,

4) If you need refrigeration capacity is not in the table and power 460/3-60Hz,you can contact us.

Zhejiang Beifeng Refrigeration Equipment Co., Ltd is a famous China Semi-Hermetic Compressor Air-Cooled Condensing Units Factory and Semi-Hermetic Compressor Air-Cooled Condensing Units Company,and the products are exported to the Europe,South East Asia,Middle East,North America,Africa etc.

Get In Touch

If you have any questions or need help, please contact us directly, we will provide you with online help and services in time.

Since 1986

Professional refrigeration equipment manufacturer

Zhejiang Beifeng Refrigeration Equipment Co., Ltd. has 35 years history of manufacturing refrigeration equipment. Currently, it has two processing bases located in Shengzhou, Zhejiang, with a production building of 60,000 square meters. It has set up three sales companies in Shanghai, Beijing, and Guangzhou, with strong technical force, advanced equipment, complete varieties and stable quality. The company has a high-quality inspection center to detect the performance index of refrigeration products and imported vacuum-type helium leak detectors for condensers and evaporators. It has a great influence in the national refrigeration industry and occupies a large market, with distributors in all major cities; It enjoys a high reputation not only in the domestic market, but also in the overseas market, and the products are exported to Europe, Southeast Asia, the Middle East, North America, Africa, etc.

Zhejiang Beifeng Refrigeration Equipment Co., Ltd.

Follow Beifeng to get the latest enterprise and refrigeration equipment products news

What’s New