In the refrigeration process, the fair design of the condenser
In the refrigeration process, the fair design of the condenser is an important part of improving the energy efficiency r...
BEIFENG BRAND FRENCH TECUMSEH COMPRESSORS & CONDENSING UNITS SERIAL SPECIFICATION
R22 MEDIUM/HIH BACK PRESSURE
Compressor models |
Nominal Power (HP.) |
Refrigerant |
Displacement (cm³) |
Expansion device |
Air Flow (m³/hr) |
Evaporating Temperature |
Voltage |
|||||
-25℃ |
-15℃ |
-10℃ |
0℃ |
+7.2℃ |
+15℃ |
|||||||
AEZ 3340EH |
1/3 |
R22 |
7.55 |
C |
800 |
256 |
444 |
548 |
788 |
988 |
1221 |
208-220V/1/50HZ |
AEZ4440EHR |
1/3 |
R22 |
7.55 |
CN |
800 |
256 |
444 |
548 |
788 |
988 |
1221 |
208-220V/1/50HZ |
AEZ 9440TMHR |
1/3 |
R22 |
7.55 |
CN |
800 |
294 |
444 |
548 |
788 |
988 |
1221 |
220-240V/1/50HZ |
CAE 9460TMHR |
1/2 |
R22 |
11.3 |
CN |
800 |
410 |
653 |
808 |
1161 |
1426 |
1739 |
208-220V/1/50HZ |
CAJ 9480TMH/HR |
5/8 |
R22 |
15.2 |
CN |
1130 |
576 |
946 |
1155 |
1632 |
2036 |
2509 |
208-220V/1/50HZ |
TAJ 9480TMH/HR |
5/8 |
R22 |
15.2 |
CN |
1130 |
576 |
946 |
1155 |
1632 |
2036 |
2509 |
400V/3/50Hz |
CAJ 9510TMH/HR |
1 |
R22 |
18.3 |
CN |
980 |
711 |
1126 |
1374 |
1941 |
2411 |
2987 |
208-220V/1/50HZ |
TAJ 9510TMH/HR |
1 |
R22 |
18.3 |
CN |
980 |
711 |
1126 |
1374 |
1941 |
2411 |
2987 |
400V/3/50HZ |
CAJ9513TMH/HR |
1-1/8 |
R22 |
24.2 |
CN |
980 |
806 |
1348 |
1666 |
2370 |
2899 |
3523 |
208-220V/1/50HZ |
TAJ9513TMH/HR |
1-1/8 |
R22 |
24.2 |
CN |
980 |
806 |
1348 |
1666 |
2370 |
2899 |
3523 |
400V/3/50HZ |
CAJ 4517EHR |
1-1/4 |
R22 |
25.95 |
CN |
2200 |
1072 |
1692 |
2071 |
2978 |
3741 |
4681 |
208-220V/1/50HZ |
TAJ 4517TH/HR |
1-1/4 |
R22 |
25.95 |
CN |
2200 |
1072 |
1692 |
2071 |
2978 |
3741 |
4681 |
400V/3/50Hz |
CAJ 4519TH/HR |
1-3/4 |
R22 |
34.45 |
CN |
2250 |
1250 |
2144 |
2642 |
3767 |
4669 |
5739 |
208-220V/1/50HZ |
TAJ 4519TH/HR |
1-3/4 |
R22 |
34.45 |
CN |
2250 |
1250 |
2144 |
2642 |
3767 |
4669 |
5739 |
400V/3/50HZ |
FH 4522FH/HR |
2 |
R22 |
40.8 |
CN |
2250 |
1348 |
2257 |
2794 |
4028 |
5053 |
6297 |
208-220V/1/50HZ |
TFH 4522FH/HR |
2 |
R22 |
40.8 |
CN |
2250 |
1348 |
2257 |
2794 |
4028 |
5053 |
6297 |
400V/3/50HZ |
FH 4524FH/HR |
2 |
R22 |
43.9 |
CN |
2250 |
1282 |
2314 |
2910 |
4200 |
5322 |
6592 |
208-220V/1/50HZ |
TFH 4524FH/HR |
2 |
R22 |
43.9 |
ON |
2250 |
1282 |
2314 |
2910 |
4200 |
5322 |
6592 |
400V/3/50Hz |
FH 4531FH/HR |
2-3/4 |
R22 |
58.1 |
CN |
4800 |
1669 |
3611 |
4360 |
6163 |
7597 |
9277 |
208-220V/1/50HZ |
TFH 4531FH/HR |
2-3/4 |
R22 |
58.1 |
CN |
4800 |
1669 |
3611 |
4360 |
6163 |
7597 |
9277 |
400V/3/50HZ |
TFH 4540FH/HR |
3-1/2 |
R22 |
74.25 |
CN |
4600 |
1890 |
4157 |
5137 |
7438 |
9194 |
11300 |
400V/3/50Hz |
TAG 4546THR |
4 |
R22 |
90.2 |
CN |
7000 |
2347 |
4486 |
5569 |
8483 |
11244 |
14507 |
400V/3/50HZ |
TAG 4553THR |
4-1/2 |
R22 |
10.7 |
CN |
7000 |
3058 |
5360 |
6635 |
9745 |
12467 |
15797 |
400V/3/50HZ |
TAG 4561THR |
5 |
R22 |
112.5 |
CN |
6600 |
3218 |
5954 |
7607 |
11447 |
14317 |
17813 |
400V/3/50Hz |
TAG 4568THR |
6 |
R22 |
124.4 |
CN |
6000 |
3320 |
6579 |
8566 |
12759 |
16221 |
20116 |
400V/3/50HZ |
TAG 4573THR |
6-1/2 |
R22 |
134.8 |
CN |
6000 |
4613 |
7033 |
8739 |
12634 |
15589 |
19298 |
400V/3/50HZ |
TAGD 4590THR |
7-1/2 |
R22 |
180.4 |
CN |
11500 |
4700 |
8309 |
10574 |
15628 |
19486 |
23990 |
400V/3/50Hz |
TAGD4610THR |
9 |
R22 |
201.7 |
CN |
11500 |
5103 |
9354 |
12058 |
17926 |
22340 |
27393 |
400V/3/50HZ |
TAGD 4612THR |
10 |
R22 |
225 |
CN |
11000 |
6604 |
11749 |
14841 |
22107 |
27561 |
34072 |
400V/3/50HZ |
TAGD4614THR |
12 |
R22 |
269.6 |
CN |
10500 |
7104 |
12055 |
15443 |
23590 |
29775 |
37160 |
400V/3/50Hz |
Performance data based on: 50Hz
Ambient Temp: 32℃
R134A MEDIUMHIGH BACK PRESSURE
Compressor models |
Nominal Power (HP.) |
Refrigerant |
Displacement (cm³) |
Expansion device |
Air Flow (m³/hr) |
Evaporating Temperature |
Voltage |
|||||
-25℃ |
-15℃ |
-10℃ |
0℃ |
+7.2℃ |
+15℃ |
|||||||
AEZ 4430YHR |
1/4 |
R134A |
8.85 |
CN |
410 |
162 |
311 |
393 |
604 |
778 |
982 |
208-220V/1/50HZ |
AEZ 3440YH |
1/3 |
R134A |
12.05 |
C |
800 |
228 |
410 |
519 |
768 |
969 |
1212 |
220-240V/1/50HZ |
CAE 4440YHR |
1/3 |
R134A |
12.05 |
CN |
800 |
228 |
410 |
519 |
768 |
969 |
1212 |
208-220V/1/50HZ |
AE 3440YH |
1/3 |
R134A |
12.05 |
C |
800 |
241 |
433 |
553 |
841 |
1081 |
1375 |
220-240V/1/50HZ |
CAE 4440YHHR |
1/3 |
R134A |
12.05 |
CN |
800 |
241 |
433 |
553 |
841 |
1081 |
1375 |
220-240V/1/50HZ |
CAE 4448YHR |
3/7 |
R134A |
14.15 |
CN |
800 |
248 |
486 |
627 |
937 |
1186 |
1482 |
208-220V/1/50HZ |
CAE 4456YHR |
7/16 |
R134A |
16 |
CN |
980 |
298 |
538 |
689 |
1034 |
1319 |
1669 |
208-220V/1/50HZ |
CAJ 4461YH/HR |
1/2 |
R134A |
18.3 |
CN |
980 |
339 |
620 |
782 |
1156 |
1475 |
1843 |
208-220V/1/50HZ |
TAJ 4461YH/HR |
1/2 |
R134A |
18.3 |
CN |
980 |
339 |
620 |
782 |
1156 |
1475 |
1843 |
400V/3/50HZ |
CAJ 4476YH/HR |
5/8 |
R134A |
21.75 |
CN |
1130 |
447 |
750 |
956 |
1446 |
1867 |
2393 |
220-240V/1/50HZ |
CAJ 4492YH/HR |
3/4 |
R134A |
25.95 |
CN |
980 |
494 |
925 |
1179 |
1742 |
2229 |
2776 |
208-220V/1/50HZ |
TAJ 4492YH/HR |
3/4 |
R134A |
25.95 |
CN |
980 |
494 |
925 |
1179 |
1742 |
2229 |
2776 |
400V/3/50HZ |
CAJ 4511YH/HR |
1 |
R134A |
32.7 |
CN |
980 |
803 |
1216 |
1478 |
2138 |
2687 |
3370 |
208-220V/1/50Hz |
TAJ 4511YH/HR |
1 |
R134A |
32.7 |
CN |
980 |
803 |
1216 |
1478 |
2138 |
2687 |
3370 |
208-220V/1/50HZ |
FH 4518YH/HR |
1-1/2 |
R134A |
53.2 |
CN |
2250 |
1163 |
1791 |
2250 |
3463 |
4488 |
5848 |
208-220V/1/50Hz |
TFH 4518YH/HR |
1-1/2 |
R134A |
53.2 |
CN |
2250 |
1163 |
1791 |
2250 |
3463 |
4488 |
5848 |
400V/3/50HZ |
FH 4525YH/HR |
2 |
R134A |
74.25 |
CN |
2250 |
1147 |
2128 |
2759 |
4154 |
5424 |
6945 |
208-220V/1/50HZ |
TFH 4525YH/HR |
2 |
R134A |
74.25 |
CN |
2250 |
1147 |
2128 |
2759 |
4154 |
5424 |
6945 |
400V/3/50HZ |
TAG 4528YH |
2-1/2 |
R134A |
90.2 |
CN |
3540 |
978 |
2302 |
3132 |
5062 |
6687 |
8697 |
400V/3/50HZ |
TAG 4534YHR |
3 |
R134A |
100.7 |
CN |
4800 |
1336 |
2818 |
3760 |
5977 |
7859 |
10184 |
400V/3/50HZ |
TAG 4537YHR |
3-1/4 |
R134A |
112.5 |
CN |
4500 |
1573 |
3258 |
4304 |
6698 |
8690 |
11133 |
400V/3/50HZ |
TAG 4543YHR |
3-1/2 |
R134A |
124.4 |
CN |
4500 |
1737 |
3493 |
4638 |
7314 |
9601 |
12443 |
400V/3/50HZ |
Performance data based on: 50Hz
Ambient Temp:32℃
R404A MEDIUM/HIGH BACK PRESSURE COMPRESSORSR
Compressor models |
Nominal Power (HP.) |
Refrigerant |
Displacement (cm³) |
Expansion device |
Air Flow (m³/hr) |
Evaporating Temperature |
Voltage |
|||||
-25℃ |
-15℃ |
-10℃ |
0℃ |
+7.2℃ |
+15℃ |
|||||||
AEZ 3440ZH |
1/3 |
R404A |
7.55 |
C |
800 |
|
448 |
552 |
783 |
970 |
1049 |
208-220V/1/50HZ |
AEZ 4440ZHR |
1/3 |
R404A |
7.55 |
CN |
800 |
|
448 |
552 |
783 |
970 |
1049 |
208-220V/1/50HZ |
AEZ 9440ZMHR |
1/3 |
R404A |
7.55 |
CN |
800 |
262 |
448 |
552 |
783 |
970 |
1049 |
220-240V/1/50HZ |
CAE 9460ZMHR |
1/2 |
R404A |
11.3 |
CN |
980 |
394 |
659 |
803 |
1117 |
1368 |
1472 |
208-220V/1/50HZ |
CAE 9470ZMHR |
9/16 |
R404A |
13.3 |
CN |
1130 |
520 |
847 |
1030 |
1441 |
1775 |
1915 |
208-220V/1/50HZ |
CAJ 9480ZMH/HR |
5/8 |
R404A |
15.2 |
CN |
1130 |
619 |
975 |
1176 |
1624 |
1992 |
2146 |
208-220V/1/50HZ |
TAJ 9480ZMH/HR |
5/8 |
R404A |
15.2 |
CN |
1130 |
619 |
975 |
1176 |
1624 |
1992 |
2146 |
400V/3/50HZ |
CAJ 9510ZMHR |
1 |
R404A |
18.3 |
CN |
980 |
773 |
1183 |
1427 |
1973 |
2398 |
2584 |
208-220V/1/50HZ |
TAJ 9510ZMHR |
1 |
R404A |
18.3 |
CN |
980 |
773 |
1183 |
1427 |
1973 |
2398 |
2584 |
400V/3/50HZ |
CAJ 9513ZMHR |
1-1/8 |
R404A |
24.2 |
CN |
980 |
861 |
1417 |
1718 |
2365 |
2869 |
3079 |
208-220V/1/50HZ |
TAJ 9513ZMHR |
1-1/8 |
R404A |
24.2 |
CN |
980 |
861 |
1417 |
1718 |
2365 |
2869 |
3079 |
400V/3/50HZ |
CAJ4517ZHR |
1-1/4 |
R404A |
25.95 |
CN |
2200 |
|
1757 |
2134 |
3029 |
3677 |
3960 |
208-220V/1/50HZ |
TAJ4517ZHR |
1-1/4 |
R404A |
25.95 |
CN |
2200 |
|
1757 |
2134 |
3029 |
3677 |
3960 |
400V/3/50HZ |
CAJ 4519ZHR |
1-3/4 |
R404A |
34.45 |
CN |
2250 |
|
2282 |
2731 |
3803 |
4643 |
5008 |
208-220V/1/50HZ |
TAJ 4519ZHR |
1-3/4 |
R404A |
34.45 |
CN |
2250 |
|
2282 |
2731 |
3803 |
4643 |
5008 |
400V/3/50HZ |
FH 4522ZHR |
2 |
R404A |
40.8 |
CN |
2250 |
|
2142 |
2664 |
3787 |
4676 |
5041 |
208-220V/1/50HZ |
TFH 4522ZHR |
2 |
R404A |
40.8 |
CN |
2250 |
|
2142 |
2664 |
3787 |
4676 |
5041 |
400V/3/50HZ |
FH 4524ZHR |
2 |
R404A |
43.9 |
CN |
2480 |
|
2397 |
2951 |
4160 |
5127 |
5529 |
208-220V/1/50HZ |
TFH 4524ZHR |
2 |
R404A |
43.9 |
CN |
2480 |
|
2397 |
2951 |
4160 |
5127 |
5529 |
400V/3/50HZ |
FH 4531ZHRE |
2-3/4 |
R404A |
58.1 |
CN |
4800 |
|
3416 |
4233 |
5990 |
7372 |
7939 |
208-220V/1/50HZ |
TFH 4531ZHR |
2-3/4 |
R404A |
58.1 |
CN |
4800 |
|
3416 |
4233 |
5990 |
7372 |
7939 |
400V/3/50HZ |
FH 4540ZHR |
3-1/2 |
R404A |
74.25 |
CN |
4800 |
|
4108 |
5016 |
7010 |
8609 |
9274 |
208-220V/1/50HZ |
TFH 4540ZHR |
3-1/2 |
R404A |
74.25 |
CN |
4800 |
|
4108 |
5016 |
7010 |
8609 |
9274 |
400V/3/50HZ |
FHD 4548ZHR |
4 |
R404A |
87.8 |
CN |
7000 |
|
4756 |
6237 |
9094 |
11059 |
11808 |
208-220V/1/50HZ |
TFHD 4548ZHR |
4 |
R404A |
87.8 |
CN |
7000 |
|
4756 |
6237 |
9094 |
11059 |
11808 |
400V/3/50HZ |
FHD 4562ZHR |
5 |
R404A |
116.2 |
CN |
6000 |
|
6673 |
8438 |
11749 |
13947 |
14767 |
208-220V/1/50HZ |
TFHD 4562ZHR |
5 |
R404A |
116.2 |
CN |
6000 |
|
6673 |
8438 |
11749 |
13947 |
14767 |
400V/3/50HZ |
TAG 4546ZHR |
4 |
R404A |
90.2 |
CN |
7000 |
|
4757 |
6013 |
8878 |
11256 |
12262 |
400V/3/50HZ |
TAG 4553ZHR |
4-1/2 |
R404A |
100.7 |
CN |
7000 |
|
5085 |
6357 |
9338 |
11769 |
12815 |
400V/3/50HZ |
TAG 4561ZHR |
5 |
R404A |
112.5 |
CN |
6600 |
|
5818 |
7351 |
10883 |
13766 |
14882 |
400V/3/50HZ |
TAG 4568ZHR |
6 |
R404A |
124.4 |
CN |
6000 |
|
6631 |
8506 |
12540 |
15550 |
16790 |
400V/3/50HZ |
TAG 4573ZHR |
6-1/2 |
R404A |
134.8 |
CN |
6000 |
|
7182 |
8881 |
12698 |
15853 |
17178 |
400V/3/50HZ |
TAGD 4590ZHR |
7-1/2 |
R404A |
180.4 |
CN |
11500 |
|
8968 |
11266 |
16265 |
20237 |
21877 |
400V/3/50HZ |
TAGD 461OZHR |
9 |
R404A |
201.4 |
CN |
11000 |
|
9796 |
12380 |
18172 |
22924 |
24918 |
400V/3/50HZ |
TAGD 4612ZHR |
10 |
R404A |
225 |
CN |
11000 |
|
12015 |
14846 |
20947 |
25768 |
27754 |
400V/3/50HZ |
TAGD 4614ZHR |
12 |
R404A |
248.8 |
CN |
10500 |
|
14074 |
17529 |
24416 |
29417 |
31386 |
400V/3/50HZ |
Performance data based on: 50Hz
Ambient Temp: 32℃
If you have any questions or need help, please contact us directly, we will provide you with online help and services in time.
Professional refrigeration equipment manufacturer
Zhejiang Beifeng Refrigeration Equipment Co., Ltd. has 35 years history of manufacturing refrigeration equipment. Currently, it has two processing bases located in Shengzhou, Zhejiang, with a production building of 60,000 square meters. It has set up three sales companies in Shanghai, Beijing, and Guangzhou, with strong technical force, advanced equipment, complete varieties and stable quality. The company has a high-quality inspection center to detect the performance index of refrigeration products and imported vacuum-type helium leak detectors for condensers and evaporators. It has a great influence in the national refrigeration industry and occupies a large market, with distributors in all major cities; It enjoys a high reputation not only in the domestic market, but also in the overseas market, and the products are exported to Europe, Southeast Asia, the Middle East, North America, Africa, etc.
In the refrigeration process, the fair design of the condenser is an important part of improving the energy efficiency r...
In industrial air conditioning refrigeration systems, evaporators, condensers, compressors and throttle valves are four ...
Different condensers according to steam condensation can be divided into surface type (also called partition type) and m...
Air coolers can be used for cooling or condensation, and are widely used in: refining, condensation of petrochemical ove...
In summer, the compressor's exhaust temperature is relatively high and the hand cannot touch it. According to national s...
An air cooler is a heat exchanger that uses air as a cooling medium to cool a warm stream to a desired temperature. Refe...