In the refrigeration process, the fair design of the condenser
In the refrigeration process, the fair design of the condenser is an important part of improving the energy efficiency r...
SEMI-HERMETIC INDUSTRIAL CHILLER
UINHT MODEL INSTRUCTION
AIR-COOLED CHILLER TECHNICAL PARAMETERS
Model Parameter |
BF-LSBF04 |
BF-LSBF05 |
BF-LSBF08 |
BF-LSBF10 |
BF-LSBF15 |
BF-LSBF20 |
BF-LSBF30 |
BF-LSBF35 |
BF-LSBF40 |
BF-LSBF50 |
BF-LSBF60 |
BF-LSBF80 |
|
Refrigerating effect Kw |
10.6 |
15.1 |
19.5 |
28.1 |
41.9 |
42.1 |
61.3 |
80.4 |
92.1 |
108.8 |
122.6 |
184.2 |
|
Total power Kw |
4.51 |
5.53 |
7.71 |
11.49 |
15.76 |
15.59 |
23.26 |
28.64 |
33.45 |
41.99 |
45.44 |
66.9 |
|
Max. running current A |
7.6 |
10.1 |
15 |
17.6 |
24.3 |
37 |
53 |
61 |
78 |
92 |
106 |
156 |
|
Power supply |
3PH/380V/50HZ |
||||||||||||
Refrigerant throttling mode |
Heat expansion valve |
||||||||||||
Refrigerant |
R22 |
||||||||||||
Refrigerating circuit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
Compressors
|
Style |
Semi-closed piston type |
|||||||||||
Model |
BFBZ4 15H |
BFBZ5 18H |
BFBZ8 27H |
BFBZ10 36H |
BFBZ15 54H |
BFBV20 56H |
BFBV30 84. 5H |
BFBW35 110. 5H |
BFBW40 126. 8H |
BFBW50 151.6H |
BFBV30 84. 5H |
BFBW40 126. 8H |
|
Power Kw |
4.15 |
5.03 |
6.81 |
10.29 |
14.2 |
14.03 |
20.92 |
26.24 |
31.05 |
38.39 |
41.84 |
62.1 |
|
Quantity |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
Condenser
|
Form |
Copper-tube aluminum-fin type |
|||||||||||
Model |
BF- NCH/0500 |
BF- NCH/0500 |
BF- NCH/1000 |
BF- NCH/1000 |
BF- NCH/1500 |
BF- NCH/2000 |
BF- NCH/3000 |
BF- NCH/4000 |
BF- NCH/4000 |
BF- NCH/5000 |
BF- HVDK500 |
BF- HVDK750N |
|
Fan Power Kw |
0.36 |
0.36 |
0.90 |
0.9 |
1.2 |
1.56 |
2.5 |
2.40 |
2.40 |
3.12 |
2.22 |
2.96 |
|
Fan Delivery m³/h |
6300 |
6300 |
12600 |
12600 |
16660 |
21000 |
31500 |
33320 |
33320 |
47000 |
45000 |
60000 |
|
Evaporator |
Form |
High-efficiency shell and tube type heat exchanger |
|||||||||||
Secondary Refrigerant |
Water, glycol |
||||||||||||
Inlet Temperature ℃ |
+ 12 |
||||||||||||
Outlet Temperature ℃ |
+ 7 |
||||||||||||
Rate of Flow m³/h |
2.4 |
3.0 |
3.6 |
5.4 |
8.1 |
8.5 |
12.1 |
15.1 |
18.1 |
21.2 |
24.2 |
36.2 |
|
Specification of connecting pipe |
1-1/2" |
1-1/2" |
1-1/2" |
1-1/2" |
2" |
2" |
2" |
2-1/2" |
2-1/2" |
2-1/2" |
3" |
3" |
|
Running control mode |
Fully automatic |
||||||||||||
Safety protection device |
The assembly unit has overload protection, the compressor has overheat protection. High and low pressure, oil pressure protection; open-phase protection; ultralow water temperature protection; flow rate protection. |
Remarks:
The working conditions of assembly unit under nominal refrigerating effect and power: condensing temperature 50℃, inlet water temperature +12℃, outlet water temperature +7℃
WATER-COOLED CHILLER TECHNICAL PARAMETERS
Model Parameter |
BF-LSB04 |
BF-LSB05 |
BF-LSB08 |
BF-LSB10 |
BF-LSB15 |
BF-LSB20 |
BF-LSB30 |
BF-LSB35 |
BF-LSB40 |
BF-LSB50 |
BF-LSB60 |
BF-LSB100 |
|
Refrigerating effect Kw |
11.2 |
15 |
21.6 |
29.3 |
43.2 |
47.9 |
69.5 |
89.8 |
102.8 |
122.8 |
139 |
245.6 |
|
Total power Kw |
3.58 |
4.48 |
6.07 |
9.11 |
12.11 |
12.34 |
18.16 |
22.82 |
26.99 |
33.18 |
36.32 |
66.36 |
|
Max. running current A |
7.6 |
10.1 |
15 |
17.6 |
24.3 |
37 |
53 |
61 |
78 |
92 |
106 |
184 |
|
Power supply |
3PH/380V/50HZ |
||||||||||||
Refrigerant throttling mode |
Heat expansion valve |
||||||||||||
Refrigerant |
R22 |
||||||||||||
Refrigerating circuit |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
Compressors |
Style |
Semi-closed piston type |
|||||||||||
Model |
BFBZ4 15H |
BFBZ5 18H |
BFBZ8 27H |
BFBZ10 36H |
BFBZ15 54H |
BFBV20 56H |
BFBV30 84.5H |
BFBW35 110.5H |
BFBW40 126.8H |
BFBW50 151.6H |
BFBV30 84.5H |
BFBW50 151.6H |
|
Quantity |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
Form |
High-efficiency shell and tube type heat exchanger | ||||||||||||
Condenser
|
Inlet water temperature ℃ |
30 |
|||||||||||
Outlet water temperature ℃ |
|
|
|
|
|
3 |
5 |
|
|
|
|
|
|
Flow rate of cooling water m³/h |
3 |
3.8 |
5.4 |
7.2 |
10.8 |
12.1 |
17.1 |
22.3 |
25.6 |
30.2 |
34.2 |
60.4 |
|
Specification of connecting pipe |
1-1/2" |
1-1/2" |
1-1/2" |
2" |
2" |
2" |
2-1/2" |
2-1/2" |
2-1/2" |
2-1/2" |
3" |
4" |
|
Evaporator
|
Form |
High-efficiency shell and tube type heat exchanger |
|||||||||||
Secondary Refrigerant |
Water, glycol |
||||||||||||
Inlet Temperature ℃ |
+ 12 |
||||||||||||
Outlet Temperature℃ |
+ 7 |
||||||||||||
Rate of Flow m³/h |
2.4 |
3.0 |
4.8 |
6.1 |
8.6 |
9.1 |
13.3 |
16.9 |
19.7 |
23.2 |
26.6 |
46.4 |
|
Specification of connecting pipe |
1-1/2" |
1-1/2" |
1-1/2" |
1-1/2" |
2" |
2" |
2-1/2" |
2-1/2" |
3" |
3" |
3" |
4" |
|
Running control mode |
Fully automatic |
||||||||||||
Safety protection device |
The assembly unit has overload protection, the compressor has overheat protection. High and low pressure, oil pressure protection; open-phase protection; ultralow water temperature protection; flow rate protection. |
Remarks:
The working conditions of assembly unit under nominal refrigerating effect and power: condensing temperature 50℃, inlet water temperature +12℃, outlet water temperature +7℃
If you have any questions or need help, please contact us directly, we will provide you with online help and services in time.
Professional refrigeration equipment manufacturer
Zhejiang Beifeng Refrigeration Equipment Co., Ltd. has 35 years history of manufacturing refrigeration equipment. Currently, it has two processing bases located in Shengzhou, Zhejiang, with a production building of 60,000 square meters. It has set up three sales companies in Shanghai, Beijing, and Guangzhou, with strong technical force, advanced equipment, complete varieties and stable quality. The company has a high-quality inspection center to detect the performance index of refrigeration products and imported vacuum-type helium leak detectors for condensers and evaporators. It has a great influence in the national refrigeration industry and occupies a large market, with distributors in all major cities; It enjoys a high reputation not only in the domestic market, but also in the overseas market, and the products are exported to Europe, Southeast Asia, the Middle East, North America, Africa, etc.
In the refrigeration process, the fair design of the condenser is an important part of improving the energy efficiency r...
In industrial air conditioning refrigeration systems, evaporators, condensers, compressors and throttle valves are four ...
Different condensers according to steam condensation can be divided into surface type (also called partition type) and m...
Air coolers can be used for cooling or condensation, and are widely used in: refining, condensation of petrochemical ove...
In summer, the compressor's exhaust temperature is relatively high and the hand cannot touch it. According to national s...
An air cooler is a heat exchanger that uses air as a cooling medium to cool a warm stream to a desired temperature. Refe...